LU-A
Small-capacity Tension/Compression Load Cell

Summary
The LU-A is a load cell for measuring small tension or compression loads. It use a straight beam as diaphragm.
Rated Capacity: ±50 to ±200 N
Diameter: 90 mm
Nonlinearity: Within ±0.3% RO
Features
• High accuracy
• Using a straight beam as diaphragm
• TEDS-installed versions can be manufactured.
Products table
All display
LU-5KA
±50 N

Specifications
Performance
Rated Capacity | ±50 N |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.2% RO |
Repeatability | 0.2% RO or less |
Rated Output | 1.5 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 75ºC |
---|---|
Compensated Temperature | -10 to 65ºC |
Temperature Effect on Zero | Within ±0.01% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±0.5% |
Output Resistance | 350 Ω ±0.5% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Natural Frequencies | Approx. 200 Hz |
Weight | Approx. 2.3 kg (Excluding cable) |
Optional Accessories | Mount base CF |
---|
Dimensions

LU-10KA
±100 N

Specifications
Performance
Rated Capacity | ±100 N |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.2% RO |
Repeatability | 0.2% RO or less |
Rated Output | 1.5 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 75ºC |
---|---|
Compensated Temperature | -10 to 65ºC |
Temperature Effect on Zero | Within ±0.01% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±0.5% |
Output Resistance | 350 Ω ±0.5% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Natural Frequencies | Approx. 330 Hz |
Weight | Approx. 2.3 kg (Excluding cable) |
Optional Accessories | Mount base CF |
---|
Dimensions

LU-20KA
±200 N

Specifications
Performance
Rated Capacity | ±200 N |
---|---|
Nonlinearity | Within ±0.3% RO |
Hysteresis | Within ±0.2% RO |
Repeatability | 0.2% RO or less |
Rated Output | 1.5 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 75ºC |
---|---|
Compensated Temperature | -10 to 65ºC |
Temperature Effect on Zero | Within ±0.01% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±0.5% |
Output Resistance | 350 Ω ±0.5% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long, terminated with a connector plug PRC03-12A10-7M (Shield wire is connected to the case.) |
Mechanical Properties
Safe Overloads | 120% |
---|---|
Natural Frequencies | Approx. 500 Hz |
Weight | Approx. 2.3 kg (Excluding cable) |
Optional Accessories | Mount base CF |
---|
Dimensions

Remarks
*CE compliant models are available. Inquiries are welcome.