LUB-C
Beam-type Load Cell

Summary
The LUB-C is a beam-type load cell, devaloped as an OME-oriented detector of weighing system.
Rated Capacity: 5 kN, 20 kN
Diameter: 38 mm (5 kN), 53 mm (20 kN)
Nonlinearity: Within ±0.05% RO
Features
• Low price
• Compact & lightweight
• High accuracy
• TEDS-installed versions can be manufactured.
Products table
All display
LUB-500KC
5 kN

Specifications
Performance
Rated Capacity | 5 kN |
---|---|
Nonlinearity | Within ±0.05% RO |
Hysteresis | Within ±0.05% RO |
Repeatability | 0.03% RO or less |
Rated Output | 2 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.003% RO/ºC |
Temperature Effect on Output | Within ±0.003%/ºC |
Electrical Characteristics
Safe Excitation | 20 V AC or DC |
---|---|
Recommended Excitation | 1 to 12 V AC or DC |
Input Resistance | 380 Ω ±8% |
Output Resistance | 350 Ω ±1% |
Cable | 4-conductor (0.14 mm2) chloroprene shielded cable, 6 mm diameter by 2 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 1.3 kHz |
Weight | Approx. 1.3 kg (Including cable) |
Optional Accessories | Patch CW Spacer LE Hanger TW |
---|
Dimensions

LUB-2TC
20 kN

Specifications
Performance
Rated Capacity | 20 kN |
---|---|
Nonlinearity | Within ±0.05% RO |
Hysteresis | Within ±0.05% RO |
Repeatability | 0.03% RO or less |
Rated Output | 2 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Compensated Temperature | -10 to 60ºC |
Temperature Effect on Zero | Within ±0.003% RO/ºC |
Temperature Effect on Output | Within ±0.003%/ºC |
Electrical Characteristics
Safe Excitation | 20 V AC or DC |
---|---|
Recommended Excitation | 1 to 12 V AC or DC |
Input Resistance | 380 Ω ±8% |
Output Resistance | 350 Ω ±1% |
Cable | 4-conductor (0.14 mm2) chloroprene shielded cable, 6 mm diameter by 2 m long, bared at the tip (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 1.3 kHz |
Weight | Approx. 2.7 kg (Including cable) |
Optional Accessories | Patch CW Spacer LE Hanger TW |
---|
Dimensions