LUR-B-SA1
Jack Load Cell

Summary

The LUR-B-SA1 is load cell for measuring loads applied to jacks.
Rated Capacity: ±10 kN to ±2 MN
Diameter: 100 mm (±10 kN), 110 mm (±20 kN), 125 mm (±30 kN, ±50 kN), 175 mm (±100 kN), 255 mm (±200 kN, ±300 kN), 330 mm (±500 kN), 430 mm (±1 MN), 530 mm (±1.5 MN), 590 mm (±2 MN)
Nonlinearity: Within ±0.2% RO for 10 kN to 200 kN, within ±0.5% RO for 300 kN to 2 MN

Features

• Installed between Jack and the target structure
• Variety of capacity
• As for the capacity of 200 kN or more, calibration is performed for compressive load only.

Products table

All display

LUR-B-10KNSA1
±10 kN

Specifications

Performance
Rated Capacity ±10 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.1% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 1.4 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-20KNSA1
±20 kN

Specifications

Performance
Rated Capacity ±20 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.1% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 2.1 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-30KNSA1
±30 kN

Specifications

Performance
Rated Capacity ±30 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.1% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 2.2 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-50KNSA1
±50 kN

Specifications

Performance
Rated Capacity ±50 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.1% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 2.2 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-100KNSA1
±100 kN

Specifications

Performance
Rated Capacity ±100 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.1% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 2.5 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-200KNSA1
±200 kN

Specifications

Performance
Rated Capacity ±200 kN
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.1% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 5.2 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-300KNSA1
±300 kN

Specifications

Performance
Rated Capacity ±300 kN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 8 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-500KNSA1
±500 kN

Specifications

Performance
Rated Capacity ±500 kN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 15 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-1MNSA1
±1 MN

Specifications

Performance
Rated Capacity ±1 MN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 55 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-1.5MNSA1
±1.5 MN

Specifications

Performance
Rated Capacity ±1.5 MN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 85 kg (Excluding cable)

Dimensions

LUR-B-SA1

LUR-B-2MNSA1
±2 MN

Specifications

Performance
Rated Capacity ±2 MN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Rated Output 1 mV/V ±1%
Environmental Characteristics
Safe Temperature -10 to 60ºC
Compensated Temperature 0 to 60ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 12 V AC or DC
Input Resistance 350 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 10 m long
Sensor side: 1108-12A-10-7M
Measuring instrument side: PRC03-12A10-7M
Mechanical Properties
Safe Overloads 200%
Weight Approx. 100 kg (Excluding cable)

Dimensions

LUR-B-SA1

Page Top

Remarks

With the capacity of 200 kN or more, calibration is performed for compression load only.