LUX-B-ID
Compact Tension/Compression Load Cell

  • TEDS

Summary

The LUX-B-ID is a compact stainless-steel load cell with waterproof connector for measuring tension or compression loads. Models for withstand to repeated bending (Flexible cable) are available.
Rated Capacity: ±50 N to ±20 kN
Diameter: 43 mm
Nonlinearity: Within ±0.1% RO for 5 kN to 20 kN, within ±0.15% RO for 50 N to 2 kN

Features

• High sensitivity
• Easy installation
• TEDS installed

Products table

All display

LUX-B-50N-ID
±50 N

LUX-B-50N-ID
  • TEDS

Specifications

Performance
Rated Capacity ±50 N
Nonlinearity Within ±0.15% RO
Hysteresis Within ±0.15% RO
Repeatability 0.05% RO or less
Rated Output 0.85 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 8 kHz
Recommended Tightening Torque Approx. 3 N·m
Materials SUS (Metallic finish)
Weight Approx. 50 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-100N-ID
±100 N

  • TEDS

Specifications

Performance
Rated Capacity ±100 N
Nonlinearity Within ±0.15% RO
Hysteresis Within ±0.15% RO
Repeatability 0.05% RO or less
Rated Output 0.9 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 11 kHz
Recommended Tightening Torque Approx. 3 N·m
Materials SUS (Metallic finish)
Weight Approx. 50 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-200N-ID
±200 N

  • TEDS

Specifications

Performance
Rated Capacity ±200 N
Nonlinearity Within ±0.15% RO
Hysteresis Within ±0.15% RO
Repeatability 0.05% RO or less
Rated Output 0.9 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 14 kHz
Recommended Tightening Torque Approx. 3 N·m
Materials SUS (Metallic finish)
Weight Approx. 50 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-500N-ID
±500 N

  • TEDS

Specifications

Performance
Rated Capacity ±500 N
Nonlinearity Within ±0.15% RO
Hysteresis Within ±0.15% RO
Repeatability 0.05% RO or less
Rated Output 0.9 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 16 kHz
Recommended Tightening Torque Approx. 10 N·m
Materials SUS (Metallic finish)
Weight Approx. 90 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-1KN-ID
±1 kN

  • TEDS

Specifications

Performance
Rated Capacity ±1 kN
Nonlinearity Within ±0.15% RO
Hysteresis Within ±0.15% RO
Repeatability 0.05% RO or less
Rated Output 0.9 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 21 kHz
Recommended Tightening Torque Approx. 10 N·m
Materials SUS (Metallic finish)
Weight Approx. 90 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-2KN-ID
±2 kN

  • TEDS

Specifications

Performance
Rated Capacity ±2 kN
Nonlinearity Within ±0.15% RO
Hysteresis Within ±0.15% RO
Repeatability 0.05% RO or less
Rated Output 1.3 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 27 kHz
Recommended Tightening Torque Approx. 10 N·m
Materials SUS (Metallic finish)
Weight Approx. 90 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-5KN-ID
±5 kN

  • TEDS

Specifications

Performance
Rated Capacity ±5 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output 1.3 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 18 kHz
Recommended Tightening Torque Approx. 80 N·m
Materials SUS (Metallic finish)
Weight Approx. 260 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-10KN-ID
±10 kN

  • TEDS

Specifications

Performance
Rated Capacity ±10 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output 1.3 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 21 kHz
Recommended Tightening Torque Approx. 80 N·m
Materials SUS (Metallic finish)
Weight Approx. 260 g (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

LUX-B-20KN-ID
±20 kN

  • TEDS

Specifications

Performance
Rated Capacity ±20 kN
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.05% RO or less
Rated Output 1.3 mV/V or more
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -10 to 70ºC
Temperature Effect on Zero Within ±0.005% RO/ºC
Temperature Effect on Output Within ±0.005%/ºC
Electrical Characteristics
Safe Excitation 15 V AC or DC
Recommended Excitation 1 to 10 V AC or DC
Input Resistance 375 Ω ±1.5%
Output Resistance 350 Ω ±1%
Dedicated Connection Cable TE-45
Cable 6-conductor (0.08 mm2) chloroprene shielded cable, 4.4 mm diameter by 3 m long
Sensor side: Terminated with a connector plug 213FCW-8P
Measuring instrument side: Bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 25 kHz
Recommended Tightening Torque Approx. 80 N·m
Materials SUS (Metallic finish)
Weight Approx. 0.3 kg (Excluding cable)
Degree of Protection IP67 (IEC 60529)
Optional Accessories Mount base CX
Ball joint TU
Whirl-stop coupling TSC
Whirl-stop brackets TS

Dimensions

LUX-B-ID

Page Top

To Ensure Safe Usage

Work is also possible if the cable is replaced with one resistant to repeated bending (flexible cable). Please add M1Z3K to the end of the model name.
If impacts are expected in receiving tension loads, select a load cell with the rated capacity higher by one rank than the operating load.

Download

Recommended products for combination