LUXT-A
High Temp. Compact Tension/Compression Load Cell

  • CE

LUXT-A

Summary

The LUXT-A is a compact load cell that enables to continuously operate under temperatures up to 195ºC.
Rated Capacity: ±500 N to ±2 kN
Diameter: 28 mm
Nonlinearity: Within ±0.5% RO

Features

• For high temperature
• Compact & lightweight

Products table

All display

LUXT-A-500N
±500 N

LUXT-A
  • CE

Specifications

Performance
Rated Capacity 500 N
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Repeatability 0.2% RO or less
Rated Output 1.0 mV/V (2000 ×10-6strain) ±20%
Environmental Characteristics
Safe Temperature -10 to 200ºC (Non-freezing or Non-condensing)
Compensated Temperature 0 to 195ºC (Non-freezing or Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 0.08 mm2, 4-conductor fluoroplastic shielded cable, 3.1 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 18 kHz
Weight Approx. 80 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP40 (JIS C 0920/IEC 60529)
Compliance Directive 2011/65/EU,(EU)2015/863(10 restricted substances) (RoHS)
[NOTE] Products with CE Marking are compliant European RoHS Directive.
Standard Accessories Hexagon nut type3 materials SUS

Dimensions

LUXT

LUXT-A-1KN
±1 kN

LUXT-A
  • CE

Specifications

Performance
Rated Capacity 1 kN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Repeatability 0.2% RO or less
Rated Output 1.0 mV/V (2000 ×10-6strain) ±20%
Environmental Characteristics
Safe Temperature -10 to 200ºC (Non-freezing or Non-condensing)
Compensated Temperature 0 to 195ºC (Non-freezing or Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 0.08 mm2, 4-conductor fluoroplastic shielded cable, 3.1 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 24 kHz
Weight Approx. 80 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP40 (JIS C 0920/IEC 60529)
Compliance Directive 2011/65/EU,(EU)2015/863(10 restricted substances) (RoHS)
Standard Accessories Hexagon nut type3 materials SUS

Dimensions

LUXT

LUXT-A-2KN
±2 kN

LUXT-A
  • CE

Specifications

Performance
Rated Capacity 2 kN
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Repeatability 0.2% RO or less
Rated Output 1.0 mV/V (2000 ×10-6strain) ±20%
Environmental Characteristics
Safe Temperature -10 to 200ºC (Non-freezing or Non-condensing)
Compensated Temperature 0 to 195ºC (Non-freezing or Non-condensing)
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
Safe Excitation 10 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 350 Ω ±5%
Output Resistance 350 Ω ±5%
Cable 0.08 mm2, 4-conductor fluoroplastic shielded cable, 3.1 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 29 kHz
Weight Approx. 80 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP40 (JIS C 0920/IEC 60529)
Compliance Directive 2011/65/EU,(EU)2015/863(10 restricted substances) (RoHS)
Standard Accessories Hexagon nut type3 materials SUS
Optional Accessories Mount base CX-4
Ball joint TU-12BT
Whirl-stop coupling TSC-4FB, TSC-4MB
Whirl-stop bracket TS-4B

Dimensions

LUXT