PAA-R
Current-output Pressure Transducer

PAA-R

Summary

The PAA-R is a strain-gage pressure transducer with a built-in amplifier and output signals from 4 to 20 mA. The cable is integrated with the PAA-R. It is suitable for inductrial equipment or pressure control system.
Rated Capacity: 500 kPa to 50 MPa
Compensated Temperature: -20 to 70ºC

Features

• Strong against noise
• High reliability
• High safe overload 200%

Products table

All display

PAA-5KR
Cable Integrated Type 500 kPa

Specifications

Performance
Rated Capacity 500 kPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-10KR
Cable Integrated Type 1 MPa

Specifications

Performance
Rated Capacity 1 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-20KR
Cable Integrated Type 2 MPa

Specifications

Performance
Rated Capacity 2 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-50KR
Cable Integrated Type 5 MPa

PAA-R

Specifications

Performance
Rated Capacity 5 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-R

PAA-100KR
Cable Integrated Type 10 MPa

Specifications

Performance
Rated Capacity 10 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-200KR
Cable Integrated Type 20 MPa

Specifications

Performance
Rated Capacity 20 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-300KR
Cable Integrated Type 30 MPa

Specifications

Performance
Rated Capacity 30 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

PAA-500KR
Cable Integrated Type 50 MPa

Specifications

Performance
Rated Capacity 50 MPa
Nonlinearity Within ±0.2% RO
Hysteresis Within ±0.2% RO
Current Output 4 to 20 mA
Environmental Characteristics
Safe Temperature -20 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.03% RO/ºC
Temperature Effect on Output Within ±0.02%/ºC
Electrical Characteristics
SN Ratio 50 dB or more
Load Resistance 0 to 500 Ω
Cutoff Frequencies of AMP 1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply 24 VDC (21 to 30 V), 30 mA or less
Cable 4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 200%
Materials Case: SUS (Metallic finish)
Liquid-contacting part: SUS 630
Weight Approx. 200 g (Excluding cable)
Degree of Protection IP64 (IEC 60529)
Mounting Screw G3/8, male
Standard Accessories Gasket (Mild copper)

Dimensions

Page Top

To Ensure Safe Usage

When using the UCAM-80A in voltage mode, use a 250 Ω resistor to convert data to voltage.

eBook

Download

Recommended products for combination