PAB-A
Absolute Pressure Transducer

PAB-A

Summary

The PAB-A is a absolute pressure transducer for measuring pressure from absolute zero.
Rated Capacity: 200 kPa abs. to 2 MPa abs.
Compensated Temperature: -20 to 70ºC

Features

• High accuracy
• High stability
• High reliability
• Widely be used in various industrial and engineering fields
• Developed for pressure measurement on airplanes and flying objects, the PAB-A pass high-temperature and vibration tests in conformity to MIL-STD-810C.

Products table

All display

PAB-A-200KP
200 kPa abs.

Specifications

Performance
Rated Capacity 200 kPa abs.
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.1% RO or less
Rated Output 2 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 8 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 367 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long
Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F
Measuring instrument side: Bared at the tip
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 5 kHz
Materials Liquid-contacting part: SUS 630
Weight Approx. 130 g (Excluding cable)
Mounting Screw 7/16-20UNF, male
Standard Accessories O-ring JIS B 2401-P15

Dimensions

PAB-A-500KP
500 kPa abs

Specifications

Performance
Rated Capacity 500 kPa abs.
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.1% RO or less
Rated Output 2 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 8 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 367 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long
Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F
Measuring instrument side: Bared at the tip
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 8 kHz
Materials Liquid-contacting part: SUS 630
Weight Approx. 130 g (Excluding cable)
Mounting Screw 7/16-20UNF, male
Standard Accessories O-ring JIS B 2401-P15

Dimensions

PAB-A-1MP
1 MPa abs.

Specifications

Performance
Rated Capacity 1 MPa abs.
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.1% RO or less
Rated Output 2 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 8 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 367 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long
Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F
Measuring instrument side: Bared at the tip
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 10 kHz
Materials Liquid-contacting part: SUS 630
Weight Approx. 130 g (Excluding cable)
Mounting Screw 7/16-20UNF, male
Standard Accessories O-ring JIS B 2401-P15

Dimensions

PAB-A-2MP
2 MPa abs.

Specifications

Performance
Rated Capacity 2 MPa abs.
Nonlinearity Within ±0.1% RO
Hysteresis Within ±0.1% RO
Repeatability 0.1% RO or less
Rated Output 2 mV/V or more
Environmental Characteristics
Safe Temperature -30 to 80ºC
Compensated Temperature -20 to 70ºC
Temperature Effect on Zero Within ±0.01% RO/ºC
Temperature Effect on Output Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation 8 V AC or DC
Recommended Excitation 1 to 3 V AC or DC
Input Resistance 367 Ω ±2%
Output Resistance 350 Ω ±2%
Cable 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long
Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F
Measuring instrument side: Bared at the tip
(Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 12 kHz
Materials Liquid-contacting part: SUS 630
Weight Approx. 130 g (Excluding cable)
Mounting Screw 7/16-20UNF, male
Standard Accessories O-ring JIS B 2401-P15

Dimensions

Page Top

Remarks

*CE compliant models are available. Inquiries are welcome.

eBook

Download

Recommended products for combination