The PAB-A is a absolute pressure transducer for measuring pressure from absolute zero. Rated Capacity: 200 kPa abs. to 2 MPa abs. Compensated Temperature: -20 to 70ºC
Features
• High accuracy • High stability • High reliability • Widely be used in various industrial and engineering fields • Developed for pressure measurement on airplanes and flying objects, the PAB-A pass high-temperature and vibration tests in conformity to MIL-STD-810C.
Products table
All display
PAB-A-200KP 200 kPa abs.
Specifications
Performance
Rated Capacity
200 kPa abs.
Nonlinearity
Within ±0.1% RO
Hysteresis
Within ±0.1% RO
Repeatability
0.1% RO or less
Rated Output
2 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.01% RO/ºC
Temperature Effect on Output
Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation
8 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
367 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Bared at the tip (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
150%
Natural Frequencies
Approx. 5 kHz
Materials
Liquid-contacting part: SUS 630
Weight
Approx. 130 g (Excluding cable)
Mounting Screw
7/16-20UNF, male
Standard Accessories
O-ring JIS B 2401-P15
Dimensions
PAB-A-500KP 500 kPa abs
Specifications
Performance
Rated Capacity
500 kPa abs.
Nonlinearity
Within ±0.1% RO
Hysteresis
Within ±0.1% RO
Repeatability
0.1% RO or less
Rated Output
2 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.01% RO/ºC
Temperature Effect on Output
Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation
8 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
367 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Bared at the tip (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
150%
Natural Frequencies
Approx. 8 kHz
Materials
Liquid-contacting part: SUS 630
Weight
Approx. 130 g (Excluding cable)
Mounting Screw
7/16-20UNF, male
Standard Accessories
O-ring JIS B 2401-P15
Dimensions
PAB-A-1MP 1 MPa abs.
Specifications
Performance
Rated Capacity
1 MPa abs.
Nonlinearity
Within ±0.1% RO
Hysteresis
Within ±0.1% RO
Repeatability
0.1% RO or less
Rated Output
2 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.01% RO/ºC
Temperature Effect on Output
Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation
8 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
367 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Bared at the tip (Shield wire is connected to the case.)
Mechanical Properties
Safe Overloads
150%
Natural Frequencies
Approx. 10 kHz
Materials
Liquid-contacting part: SUS 630
Weight
Approx. 130 g (Excluding cable)
Mounting Screw
7/16-20UNF, male
Standard Accessories
O-ring JIS B 2401-P15
Dimensions
PAB-A-2MP 2 MPa abs.
Specifications
Performance
Rated Capacity
2 MPa abs.
Nonlinearity
Within ±0.1% RO
Hysteresis
Within ±0.1% RO
Repeatability
0.1% RO or less
Rated Output
2 mV/V or more
Environmental Characteristics
Safe Temperature
-30 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.01% RO/ºC
Temperature Effect on Output
Within ±0.01%/ºC
Electrical Characteristics
Safe Excitation
8 V AC or DC
Recommended Excitation
1 to 3 V AC or DC
Input Resistance
367 Ω ±2%
Output Resistance
350 Ω ±2%
Cable
4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Bared at the tip (Shield wire is connected to the case.)