PAG-2KA
Highly Stable Current-output Pressure Transducer

Summary
The PAG-A is a highly stable current-output pressure transducer and output signals from 4 to 20 mA. It is hermetically-sealed structure with inert gas filled in. The amplifier enables to provide high-frequency radio noise resistant.
Rated Capacity: 200 kPa
Compensated Temperature: -20 to 70ºC
Features
• High reliability
• High resolution
• Strong against noise
Products table
All display
PAG-2KA
200 kPa

Specifications
Performance
Rated Capacity | 200 kPa |
---|---|
Nonlinearity | Within ±0.1% RO |
Hysteresis | Within ±0.2% RO |
Current Output | 4 to 20 mA |
Environmental Characteristics
Safe Temperature | -20 to 75ºC |
---|---|
Compensated Temperature | -20 to 70ºC |
Temperature Effect on Zero | Within ±0.03% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Zero Stability | Within ±0.5% RO/year |
Electrical Characteristics
SN Ratio | 60 dB or more |
---|---|
Load Resistance | 0 to 500 Ω |
Cutoff Frequencies of AMP | 650 Hz (Amplitude ratio at cutoff point -3 ±1 dB) |
Power Supply | 24 VDC (21 to 30 V), 30 mA or less |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 5 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Bared at the tip (Use 3 conductors only.) (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Materials | Case: SUS (Metallic finish) Liquid-contacting part: SUS 630 |
Weight | Approx. 270 g (Excluding cable) |
Degree of Protection | IP62 (IEC 60529) |
Mounting Screw | G3/8, male |
Standard Accessories | Gasket (Mild copper) |
---|