The PAV-R is a strain-gage pressure transducer with a built-in amplifier and output voltage signals from 0 to 5V. The cable is integrated with the PAV-R. It is suitable for inductrial equipment or pressure control system. Rated Capacity: 1 to 50 MPa Compensated Temperature: -20 to 70ºC
Features
• Strong against noise • High reliability • High safe overload 200%
Products table
All display
PAV-10KR Cable Integrated Type 1 MPa
Specifications
Performance
Rated Capacity
1 MPa
Nonlinearity
Within ±0.2% RO
Hysteresis
Within ±0.2% RO
Voltage Output
0 to 5 V
Environmental Characteristics
Safe Temperature
-20 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.03% RO/ºC
Temperature Effect on Output
Within ±0.02%/ºC
Electrical Characteristics
SN Ratio
50 dB or more
Load Resistance
1 kΩ or more
Cutoff Frequencies of AMP
1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply
12 VDC (10.5 to 15 V), 30 mA or less
Cable
4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Materials
Case: SUS (Metallic finish) Liquid-contacting part: SUS 630
Weight
Approx. 200 g (Excluding cable)
Degree of Protection
IP52 (IEC 60529)
Mounting Screw
G3/8, male
Standard Accessories
Gasket (Mild copper)
Dimensions
PAV-50KR Cable Integrated Type 5 MPa
Specifications
Performance
Rated Capacity
5 MPa
Nonlinearity
Within ±0.2% RO
Hysteresis
Within ±0.2% RO
Voltage Output
0 to 5 V
Environmental Characteristics
Safe Temperature
-20 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.03% RO/ºC
Temperature Effect on Output
Within ±0.02%/ºC
Electrical Characteristics
SN Ratio
50 dB or more
Load Resistance
1 kΩ or more
Cutoff Frequencies of AMP
1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply
12 VDC (10.5 to 15 V), 30 mA or less
Cable
4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Materials
Case: SUS (Metallic finish) Liquid-contacting part: SUS 630
Weight
Approx. 200 g (Excluding cable)
Degree of Protection
IP52 (IEC 60529)
Mounting Screw
G3/8, male
Standard Accessories
Gasket (Mild copper)
Dimensions
PAV-100KR Cable Integrated Type 10 MPa
Specifications
Performance
Rated Capacity
10 MPa
Nonlinearity
Within ±0.2% RO
Hysteresis
Within ±0.2% RO
Voltage Output
0 to 5 V
Environmental Characteristics
Safe Temperature
-20 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.03% RO/ºC
Temperature Effect on Output
Within ±0.02%/ºC
Electrical Characteristics
SN Ratio
50 dB or more
Load Resistance
1 kΩ or more
Cutoff Frequencies of AMP
1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply
12 VDC (10.5 to 15 V), 30 mA or less
Cable
4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Materials
Case: SUS (Metallic finish) Liquid-contacting part: SUS 630
Weight
Approx. 200 g (Excluding cable)
Degree of Protection
IP52 (IEC 60529)
Mounting Screw
G3/8, male
Standard Accessories
Gasket (Mild copper)
Dimensions
PAV-200KR Cable Integrated Type 20 MPa
Specifications
Performance
Rated Capacity
20 MPa
Nonlinearity
Within ±0.2% RO
Hysteresis
Within ±0.2% RO
Voltage Output
0 to 5 V
Environmental Characteristics
Safe Temperature
-20 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.03% RO/ºC
Temperature Effect on Output
Within ±0.02%/ºC
Electrical Characteristics
SN Ratio
50 dB or more
Load Resistance
1 kΩ or more
Cutoff Frequencies of AMP
1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply
12 VDC (10.5 to 15 V), 30 mA or less
Cable
4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Materials
Case: SUS (Metallic finish) Liquid-contacting part: SUS 630
Weight
Approx. 200 g (Excluding cable)
Degree of Protection
IP52 (IEC 60529)
Mounting Screw
G3/8, male
Standard Accessories
Gasket (Mild copper)
Dimensions
PAV-300KR Cable Integrated Type 30 MPa
Specifications
Performance
Rated Capacity
30 MPa
Nonlinearity
Within ±0.2% RO
Hysteresis
Within ±0.2% RO
Voltage Output
0 to 5 V
Environmental Characteristics
Safe Temperature
-20 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.03% RO/ºC
Temperature Effect on Output
Within ±0.02%/ºC
Electrical Characteristics
SN Ratio
50 dB or more
Load Resistance
1 kΩ or more
Cutoff Frequencies of AMP
1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply
12 VDC (10.5 to 15 V), 30 mA or less
Cable
4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Materials
Case: SUS (Metallic finish) Liquid-contacting part: SUS 630
Weight
Approx. 200 g (Excluding cable)
Degree of Protection
IP52 (IEC 60529)
Mounting Screw
G3/8, male
Standard Accessories
Gasket (Mild copper)
Dimensions
PAV-500KR Cable Integrated Type 50 MPa
Specifications
Performance
Rated Capacity
50 MPa
Nonlinearity
Within ±0.2% RO
Hysteresis
Within ±0.2% RO
Voltage Output
0 to 5 V
Environmental Characteristics
Safe Temperature
-20 to 80ºC
Compensated Temperature
-20 to 70ºC
Temperature Effect on Zero
Within ±0.03% RO/ºC
Temperature Effect on Output
Within ±0.02%/ºC
Electrical Characteristics
SN Ratio
50 dB or more
Load Resistance
1 kΩ or more
Cutoff Frequencies of AMP
1 kHz (Amplitude ratio at cutoff point -3 ±1 dB)
Power Supply
12 VDC (10.5 to 15 V), 30 mA or less
Cable
4-conductor (0.18 mm2) vinyl shielded cable, 4.6 mm diameter by 3 m long, bared at the tip (Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads
200%
Materials
Case: SUS (Metallic finish) Liquid-contacting part: SUS 630