PDS-A
Minute Differential Pressure Transducer

PDS-A

Summary

The PDS-A is a minute differential pressure transducer with diffusional semiconductor strain gages on a silicon diaphragm. It is suitable for wind-pressure measurement.

Rated Capacity: 1 to 7 kPa
Compensated Temperature: 0 to 50ºC

Features

• High frequency response
• High sensitivity
• Noise resistant

Products table

All display

PDS-10GA
1 kPa

PDS-A

Specifications

Performance
Rated Capacity 1 kPa
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.3% RO
Rated Output 7 to 23 mV
Rated Output Accuracy Within ±1.0% RO
(Sensitivity error due to load direction)
Environmental Characteristics
Safe Temperature -20 to 70ºC
Safe Humidity 20 to 85% (At 0 to 50°C )
Compensated Temperature 0 to 50ºC
Temperature Effect on Zero Within ±0.1% RO/ºC
Temperature Effect on Output Within ±0.1%/ºC
Pressure Medium General air (Non-corrosive gas)
Electrical Characteristics
Initial Unbalance Within ±10 mV
Bridge Output Resistance 2 to 6 kΩ
Power Supply 10 VDC (9.5 to 15 V), 5 mA or less
(Bridge power supply of strain measuring instrument may be used.)
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 600%
Maximum Line Pressure 100 kPa
Natural Frequencies Approx. 1.7 kHz
Weight Approx. 40 g (Excluding cable)
Posture Effect Zero drift: Within ±0.8% RO
when inclined by 90º referring to horizontal condition
Internal Volume High side: Approx. 0.2 × 10-63(0.2 ml)
Low side: Approx. 1 × 10-63(1 ml)
Pressure Connection 4.7 mm diameter barb fitting

Dimensions

PDS-A

PDS-25GA
2.5 kPa

PDS-A

Specifications

Performance
Rated Capacity 2.5 kPa
Nonlinearity Within ±0.7% RO
Hysteresis Within ±0.3% RO
Rated Output 13 to 23 mV
Rated Output Accuracy Within ±1.0% RO
(Sensitivity error due to load direction)
Environmental Characteristics
Safe Temperature -20 to 70ºC
Safe Humidity 20 to 85% (At 0 to 50°C )
Compensated Temperature 0 to 50ºC
Temperature Effect on Zero Within ±0.08% RO/ºC
Temperature Effect on Output Within ±0.08%/ºC
Pressure Medium General air (Non-corrosive gas)
Electrical Characteristics
Initial Unbalance Within ±10 mV
Bridge Output Resistance 2 to 6 kΩ
Power Supply 10 VDC (9.5 to 15 V), 5 mA or less
(Bridge power supply of strain measuring instrument may be used.)
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 300%
Maximum Line Pressure 100 kPa
Natural Frequencies Approx. 1.7 kHz
Weight Approx. 40 g (Excluding cable)
Posture Effect Zero drift: Within ±0.3% RO
when inclined by 90º referring to horizontal condition
Internal Volume High side: Approx. 0.2 × 10-63(0.2 ml)
Low side: Approx. 1 × 10-63(1 ml)
Pressure Connection 4.7 mm diameter barb fitting

Dimensions

PDS-A

PDS-50GA
5 kPa

PDS-A

Specifications

Performance
Rated Capacity 5 kPa
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.3% RO
Rated Output 13 to 23 mV
Rated Output Accuracy Within ±1.5% RO
(Sensitivity error due to load direction)
Environmental Characteristics
Safe Temperature -20 to 70ºC
Safe Humidity 20 to 85% (At 0 to 50°C )
Compensated Temperature 0 to 50ºC
Temperature Effect on Zero Within ±0.08% RO/ºC
Temperature Effect on Output Within ±0.08%/ºC
Pressure Medium General air (Non-corrosive gas)
Electrical Characteristics
Initial Unbalance Within ±10 mV
Bridge Output Resistance 2 to 6 kΩ
Power Supply 10 VDC (9.5 to 15 V), 5 mA or less
(Bridge power supply of strain measuring instrument may be used.)
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 300%
Maximum Line Pressure 100 kPa
Natural Frequencies Approx. 1.7 kHz
Weight Approx. 40 g (Excluding cable)
Posture Effect Zero drift: Within ±0.3% RO
when inclined by 90º referring to horizontal condition
Internal Volume High side: Approx. 0.2 × 10-63(0.2 ml)
Low side: Approx. 1 × 10-63(1 ml)
Pressure Connection 4.7 mm diameter barb fitting

Dimensions

PDS-A

PDS-70GA
7 kPa

PDS-A

Specifications

Performance
Rated Capacity 7 kPa
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.3% RO
Rated Output 13 to 23 mV
Rated Output Accuracy Within ±2.0% RO
(Sensitivity error due to load direction)
Environmental Characteristics
Safe Temperature -20 to 70ºC
Safe Humidity 20 to 85% (At 0 to 50°C )
Compensated Temperature 0 to 50ºC
Temperature Effect on Zero Within ±0.08% RO/ºC
Temperature Effect on Output Within ±0.08%/ºC
Pressure Medium General air (Non-corrosive gas)
Electrical Characteristics
Initial Unbalance Within ±10 mV
Bridge Output Resistance 2 to 6 kΩ
Power Supply 10 VDC (9.5 to 15 V), 5 mA or less
(Bridge power supply of strain measuring instrument may be used.)
Cable 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, terminated with a connector plug PRC03-12A10-7M
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 300%
Maximum Line Pressure 100 kPa
Natural Frequencies Approx. 1.7 kHz
Weight Approx. 40 g (Excluding cable)
Posture Effect Zero drift: Within ±0.3% RO
when inclined by 90º referring to horizontal condition
Internal Volume High side: Approx. 0.2 × 10-63(0.2 ml)
Low side: Approx. 1 × 10-63(1 ml)
Pressure Connection 4.7 mm diameter barb fitting

Dimensions

PDS-A

Page Top

To Ensure Safe Usage

● Avoid dew condensation or freeze because the transducer is not drip-proof.
● If using as a gage pressure meter, apply pressure to the HIGH side, and open the LOW side to the atmosphere.
● For atmospheric observation, prepare piping to prevent rainwater from entering the pressure inlet.
● When using the bridge power supply of a strain amplifier, use a model (CDV-900A, WGA-710C)which supports 10 VDC.
● The suitable power supply is a series regulator type which generates less noise than the switching type.

Remarks

(Note 1) Use the transducer with general air
(Note 2) If water or any other liquid enters the low side, the transducer gets out of order.