PDV-A
Minute Differential Pressure Transducer

Summary
Minute Differential Pressure Transducer PDV-A has diffusional semiconductor strain gages on a silicon diaphragm.
It is suitable for wind-pressure measurement.
Rated Capacity: 1 to 7 kPa
Features
• High frequency response
• High sensitivity
• Noise resistant
• Voltage output of ±5 V
• Compact & lightweight
Products table
All display
PDV-10GA
1 kPa

Specifications
Performance
Rated Capacity | 1 kPa |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.3% RO |
Rated Output | 5 V |
Rated Output Accuracy | Within ±1.0% RO (Sensitivity error due to load direction) |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Safe Humidity | 20 to 85% (At 0 to 50°C) |
Compensated Temperature | 0 to 50ºC |
Temperature Effect on Zero | Within ±0.1% RO/ºC |
Temperature Effect on Output | Within ±0.1%/ºC |
Pressure Medium | General air (Non-corrosive gas) |
Electrical Characteristics
Load Resistance | 5 kΩ or more |
---|---|
Power Supply | 12 VDC (11 to 15 V), 30 mA or less |
Cable | 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, bared at the tip |
Mechanical Properties
Safe Overloads | 600% |
---|---|
Maximum Line Pressure | 100 kPa |
Natural Frequencies | Approx. 1.7 kHz |
Weight | Approx. 100 g (Excluding cable) |
Posture Effect | Zero drift: Within ±0.8% RO when inclined by 90º referring to horizontal condition |
Internal Volume | High side: Approx. 0.2 x 10-6 m3 (0.2 mL) Low side: Approx. 1 x 10-6 m3 (1 mL) |
Pressure Connection | 4.7 mm diameter barb fitting |
Dimensions

PDV-25GA
2.5 kPa

Specifications
Performance
Rated Capacity | 2.5 kPa |
---|---|
Nonlinearity | Within ±0.7% RO |
Hysteresis | Within ±0.3% RO |
Rated Output | 5 V |
Rated Output Accuracy | Within ±1.0% RO (Sensitivity error due to load direction) |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Safe Humidity | 20 to 85% (At 0 to 50°C) |
Compensated Temperature | 0 to 50ºC |
Temperature Effect on Zero | Within ±0.08% RO/ºC |
Temperature Effect on Output | Within ±0.08%/ºC |
Pressure Medium | General air (Non-corrosive gas) |
Electrical Characteristics
Load Resistance | 5 kΩ or more |
---|---|
Power Supply | 12 VDC (11 to 15 V), 30 mA or less |
Cable | 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, bared at the tip |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Maximum Line Pressure | 100 kPa |
Natural Frequencies | Approx. 1.7 kHz |
Weight | Approx. 100 g (Excluding cable) |
Posture Effect | Zero drift: Within ±0.3% RO when inclined by 90º referring to horizontal condition |
Internal Volume | High side: Approx. 0.2 x 10-6 m3 (0.2 mL) Low side: Approx. 1 x 10-6 m3 (1 mL) |
Pressure Connection | 4.7 mm diameter barb fitting |
Dimensions

PDV-50GA
5 kPa

Specifications
Performance
Rated Capacity | 5 kPa |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.3% RO |
Rated Output | 5 V |
Rated Output Accuracy | Within ±1.5% RO (Sensitivity error due to load direction) |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Safe Humidity | 20 to 85% (At 0 to 50°C) |
Compensated Temperature | 0 to 50ºC |
Temperature Effect on Zero | Within ±0.08% RO/ºC |
Temperature Effect on Output | Within ±0.08%/ºC |
Pressure Medium | General air (Non-corrosive gas) |
Electrical Characteristics
Load Resistance | 5 kΩ or more |
---|---|
Power Supply | 12 VDC (11 to 15 V), 30 mA or less |
Cable | 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, bared at the tip |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Maximum Line Pressure | 100 kPa |
Natural Frequencies | Approx. 1.7 kHz |
Weight | Approx. 100 g (Excluding cable) |
Posture Effect | Zero drift: Within ±0.3% RO when inclined by 90º referring to horizontal condition |
Internal Volume | High side: Approx. 0.2 x 10-6 m3 (0.2 mL) Low side: Approx. 1 x 10-6 m3 (1 mL) |
Pressure Connection | 4.7 mm diameter barb fitting |
Dimensions

PDV-70GA
7 kPa

Specifications
Performance
Rated Capacity | 7 kPa |
---|---|
Nonlinearity | Within ±0.5% RO |
Hysteresis | Within ±0.3% RO |
Rated Output | 5 V |
Rated Output Accuracy | Within ±2.0% RO (Sensitivity error due to load direction) |
Environmental Characteristics
Safe Temperature | -20 to 70ºC |
---|---|
Safe Humidity | 20 to 85% (At 0 to 50°C) |
Compensated Temperature | 0 to 50ºC |
Temperature Effect on Zero | Within ±0.08% RO/ºC |
Temperature Effect on Output | Within ±0.08%/ºC |
Pressure Medium | General air (Non-corrosive gas) |
Electrical Characteristics
Load Resistance | 5 kΩ or more |
---|---|
Power Supply | 12 VDC (11 to 15 V), 30 mA or less |
Cable | 4-conductor (0.05 mm2) chloroprene shielded cable, 3 mm diameter by 3 m long, bared at the tip |
Mechanical Properties
Safe Overloads | 300% |
---|---|
Maximum Line Pressure | 100 kPa |
Natural Frequencies | Approx. 1.7 kHz |
Weight | Approx. 100 g (Excluding cable) |
Posture Effect | Zero drift: Within ±0.3% RO when inclined by 90º referring to horizontal condition |
Internal Volume | High side: Approx. 0.2 x 10-6 m3 (0.2 mL) Low side: Approx. 1 x 10-6 m3 (1 mL) |
Pressure Connection | 4.7 mm diameter barb fitting |
Dimensions

To Ensure Safe Usage
• Avoid dew condensation or freeze because the transducer is not drip-proof.
• When using for a pressure meter, apply pressure to the high side and open the low side to the atmosphere.
• For atmospheric observation, prepare piping to prevent rainwater from entering the pressure inlet.
Remarks
(Note 1) Use the transducer with general air.
(Note 2) If water or any other liquid enters the low-pressure line the transducer gets out of order.