PG-H
Pressure Transducer

Summary
The PG-H is a pressure transducer with hermetically sealed with inert gas filled in.
Rated Capacity: 100, 200 MPa
Compensated Temperature: -10 to 70ºC
Features
• Highly reliable
• Highly accurate
• High strength
Products table
All display
PG-1TH
100 MPa

Specifications
Performance
Rated Capacity | 100 MPa |
---|---|
Nonlinearity | Within ±0.2% RO |
Hysteresis | Within ±0.2% RO |
Repeatability | 0.15% RO or less |
Rated Output | 1.5 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 80ºC |
---|---|
Compensated Temperature | -10 to 70ºC |
Temperature Effect on Zero | Within ±0.02% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±1.5% |
Output Resistance | 350 Ω ±1.5% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Terminated with a connector plug PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 250 kHz |
Material | Case: Stainless steel Liquid-contacting part: SUS 630 |
Weight | Approx. 220 g (Excluding cable) |
Degree of Protection | IP52 (IEC 60529) |
Mounting Screw | G1/2, male |
Standard Accessories | Gasket (Mild copper) |
---|
Dimensions

PG-2TH
200 MPa

Specifications
Performance
Rated Capacity | 200 MPa |
---|---|
Nonlinearity | Within ±0.2% RO |
Hysteresis | Within ±0.2% RO |
Repeatability | 0.15% RO or less |
Rated Output | 1.5 mV/V ±0.5% |
Environmental Characteristics
Safe Temperature | -20 to 80ºC |
---|---|
Compensated Temperature | -10 to 70ºC |
Temperature Effect on Zero | Within ±0.02% RO/ºC |
Temperature Effect on Output | Within ±0.01%/ºC |
Electrical Characteristics
Safe Excitation | 15 V AC or DC |
---|---|
Recommended Excitation | 1 to 10 V AC or DC |
Input Resistance | 350 Ω ±1.5% |
Output Resistance | 350 Ω ±1.5% |
Cable | 4-conductor (0.3 mm2) chloroprene shielded cable, 7.6 mm diameter by 3 m long Sensor side: Terminated with a waterproof connector plug 1108-12A10-7F Measuring instrument side: Terminated with a connector plug PRC03-12A10-7M (Shield wire is not connected to the case.) |
Mechanical Properties
Safe Overloads | 150% |
---|---|
Natural Frequencies | Approx. 250 kHz |
Material | Case: Stainless steel Liquid-contacting part: SUS 630 |
Weight | Approx. 220 g (Excluding cable) |
Degree of Protection | IP52 (IEC 60529) |
Mounting Screw | G1/2, male |
Standard Accessories | Gasket (Mild copper) |
---|
Dimensions

Remarks
*CE compliant models are available. Inquiries are welcome.