PSM-AB
Miniature Pressure Sensor

Summary

The PSM-AB is a miniature pressure sensor with a flurocarbon resin cable. It adopts quarter-bridge 3-wire mode and configures a full bridge by a bridge adapter.
Rated Capacity: 100, 200 kPa
Compensated Temperature: 0 to 50ºC

Features

• Bridge adapters are standard provided
• Installed by adhesives
• Pressure measurement of denser points than conventional models is possible.

Products table

All display

PSM-1KAB
100 kPa

Specifications

Performance
Rated Capacity 100 kPa
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.275 mV/V ±25%
Note: Rated output is sorted to one of the classes divided by every 0.007 mV/V difference in output value. Since the rated output stated in the Test Data Sheet is the center value of the class, it may have a maximum error of ±0.0035 mV/V.
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature 0 to 50ºC
Temperature Effect on Zero Within ±1% RO/ºC
Temperature Effect on Output Within ±0.3%/ºC
Electrical Characteristics
Safe Excitation 5 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 350 Ω ±1%
Output Resistance 350 Ω ±1%
Cable Sensor side: 3-conductor fluoroplastic coated cable,
0.25 mm diameter by 50 cm long
Measuring instrument side: 4-conductor vinyl
coated cable, 1.3 mm diameter by 15 cm long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 3 kHz
Weight Approx. 0.5 g
(Including cable but not bridge adapter)
Degree of Protection IP61 (IEC 60529) (Excluding bridge adapters)
Dedicated Adhesive RC-19 (Request the RC-19 when ordering the transducer. Free of charge.)

Dimensions

PSM-AB

PSM-2KAB
200 kPa

Specifications

Performance
Rated Capacity 200 kPa
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Rated Output 0.38 mV/V ±25%
Note: Rated output is sorted to one of the classes divided by every 0.007 mV/V difference in output value. Since the rated output stated in the Test Data Sheet is the center value of the class, it may have a maximum error of ±0.0035 mV/V.
Environmental Characteristics
Safe Temperature -20 to 70ºC
Compensated Temperature 0 to 50ºC
Temperature Effect on Zero Within ±0.5% RO/ºC
Temperature Effect on Output Within ±0.3%/ºC
Electrical Characteristics
Safe Excitation 5 V AC or DC
Recommended Excitation 2 V AC or DC
Input Resistance 350 Ω ±1%
Output Resistance 350 Ω ±1%
Cable Sensor side: 3-conductor fluoroplastic coated cable,
0.25 mm diameter by 50 cm long
Measuring instrument side: 4-conductor vinyl
coated cable, 1.3 mm diameter by 15 cm long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 3 kHz
Weight Approx. 0.5 g
(Including cable but not bridge adapter)
Degree of Protection IP61 (IEC 60529) (Excluding bridge adapters)
Dedicated Adhesive RC-19 (Request the RC-19 when ordering the transducer. Free of charge.)

Dimensions

PSM-AB

Page Top

To Ensure Safe Usage

(Note 1) Copper alloy is used for sensing element. Avoid measuring corrosive liquid or gas.
(Note 2) The mainframe has been assembled using an epoxy adhesive. Do not therefore use the transducer to measure organic solvent. (e.g. Toluene, ketone and others)