LAT-1000A series
6-component Force Measuring System

Summary

The LAT-1000A series is a 6-component force measuring system. It consists of a 6-component force transducer LAT-A and a signal processor FDP-106A.
Rated Capacity: 300 N
Diameter: 70 mm
Nonlinearity: Within ±0.5% RO

Features

• Highly accurate measurement possible even under multiple component force applied
• The compact & lightweight transducer is strain gage based and is cased with a highly rigid special aluminum alloy.
• Alarm output is set by a 2-step adjuster.

Contents

∙ 6-component force transducer LAT-A
∙ Signal processor FDP-106A
∙ PC (not included)

Products table

All display

LAT-1030KA-1
Mx, My, Mz: 10 N·m

General Specifications

Rated Capacity Fx 300 N
Rated Capacity Fy 300 N
Rated Capacity Fz 300 N
Rated Capacity Mx 10 N·m
Rated Capacity My 10 N·m
Rated Capacity Mz 10 N·m
Safe Overloads 120%
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Interference ±0.8% RO
Maximum Error ±1.5% RO
Resolution 0.05% FS
Temperature Effect on Zero Within ±0.25% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Compensated Temperature 0 to 50ºC

6-Component Force Transducer LAT-A Specifications

Rated Capacity Fx, Fy, Fz=300 N
Mx, My, Mz=10 N·m
Safe Overloads 120%
Natural Frequencies Fx, Fy: Approx. 2.3 kHz, Fz: Approx. 5.5 kHz
Mx, My: Approx. 8 kHz, Mz: Approx. 4 kHz
Recommended Excitation 2.5V DC
Safe Excitation 5V DC
Input Resistance 58.3 Ω ±10%
Output Resistance 350 Ω ±2%
Compensated Temperature 0 to 60ºC
Safe Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Weight Each model approx. 250 g (Excluding cable)
Degrees of Protection IP30 (IEC 60529)
Cable Connection cable N-78 is a standard accessory. (For connecting the LAT-A and FDP-106A.)
14-conductor (0.3 mm2) PVC shielded cable, 9 mm diameter
Sensor side: Terminated with a connector plug PRC04-12A16-14
Measuring instrument side: Dedicated plug 17JE-23150-02 (D8A).
(Shield wire is not connected to the case.)
For displacement and angle of inclination, contact us.
Standard Accessories Communications program (WindowsR version),
torque wrench, hexagon socket wrench, parallel
pins φ4 and φ8, connection cable N-78

Signal Processor FDP-106A Specifications

Input Channels: Max. 6 (6-component force)
Zero balance adjustment: Automatic
Bridge excitation voltage: 2.5 VDC
Analog Output Channels: 6
Output: ±5 V (150% the rated output of 6-component force transducer may be made ±5 V)
Resolution: 0.05% FS
Frequency response: DC to approx. 300 Hz
Initial setting: ±5V analog output for the rated capacity of 6-component force transducer, 0 mm for coordinates X, Y and Z at the load point
Serial Interface RS-232C
Transmission mode: Start-stop synchronized mode
Baud rate: 9600 bps fixed
Data: 8 bits
Parity: None
Stop bit: 1
Transmission contents: Data, setting conditions
Data format: Binary or ASCII
Connector: D-Sub 25 pins, female
PC connection: Optional interface cable for RS-232C
Sampling Frequencies When not using digital output
0.72 ms/6-channel (Cutoff frequency 366 Hz)
When using digital output
22.9 ms/6-channel in binary format (Cutoff frequency 11 Hz)
45.7 ms/6-channel in ASCII format (Cutoff frequency 6 Hz)
Nonlinearity Within ±0.05% FS
Calculation Error of Compensating Interference Within ±0.1% FS
Stability Zero ±0.25 μV/V per ºC, Sensitivity ±0.01%/ºC
Functions Over input checking, automatic zero balance,
load point correction, alarm
Monitor Indicator LED
Alarm Output Open collector
Power Supply 100 VAC (200 VAC models are also available.)
Operating Temperature 0 to 50°C
Operating Humidity 95% RH or less (Non-condensing)
Dimensions 255 W x 88 H x 180 D mm (Excluding protrusions)
Weight Approx. 2.5 kg
Standard Accessories Output cable U-58 (6 pc)
AC power cable P-18 with conversion adapter CM-39
Optional Accessories RS cross cable N-23
Mounting fixture FL-1A

Dimensions

LAT-A

LAT-1030KA-2
Mx, My, Mz: 20 N·m

General Specifications

Rated Capacity Fx 300 N
Rated Capacity Fy 300 N
Rated Capacity Fz 300 N
Rated Capacity Mx 20 N·m
Rated Capacity My 20 N·m
Rated Capacity Mz 20 N·m
Safe Overloads 120%
Nonlinearity Within ±0.5% RO
Hysteresis Within ±0.5% RO
Interference ±0.8% RO
Maximum Error ±3% RO
Resolution 0.05% FS
Temperature Effect on Zero Within ±0.25% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Compensated Temperature 0 to 50ºC

6-Component Force Transducer LAT-A Specifications

Rated Capacity Fx, Fy, Fz=300 N
Mx, My, Mz=20 N·m
Safe Overloads 120%
Natural Frequencies Fx, Fy: Approx. 2.3 kHz, Fz: Approx. 5.5 kHz
Mx, My: Approx. 8 kHz, Mz: Approx. 4 kHz
Recommended Excitation 2.5V DC
Safe Excitation 5V DC
Input Resistance 58.3 Ω ±10%
Output Resistance 350 Ω ±2%
Compensated Temperature 0 to 60ºC
Safe Temperature 0 to 70ºC
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Weight Each model approx. 250 g (Excluding cable)
Degrees of Protection IP30 (IEC 60529)
Cable Connection cable N-78 is a standard accessory. (For connecting the LAT-A and FDP-106A.)
14-conductor (0.3 mm2) PVC shielded cable, 9 mm diameter
Sensor side: Terminated with a connector plug PRC04-12A16-14
Measuring instrument side: Dedicated plug 17JE-23150-02 (D8A).
(Shield wire is not connected to the case.)
For displacement and angle of inclination, contact us.
Standard Accessories Communications program (WindowsR version),
torque wrench, hexagon socket wrench, parallel
pins φ4 and φ8, connection cable N-78

Signal Processor FDP-106A Specifications

Input Channels: Max. 6 (6-component force)
Zero balance adjustment: Automatic
Bridge excitation voltage: 2.5 VDC
Analog Output Channels: 6
Output: ±5 V (150% the rated output of 6-component force transducer may be made ±5 V)
Resolution: 0.05% FS
Frequency response: DC to approx. 300 Hz
Initial setting: ±5V analog output for the rated capacity of 6-component force transducer, 0 mm for coordinates X, Y and Z at the load point
Serial Interface RS-232C
Transmission mode: Start-stop synchronized mode
Baud rate: 9600 bps fixed
Data: 8 bits
Parity: None
Stop bit: 1
Transmission contents: Data, setting conditions
Data format: Binary or ASCII
Connector: D-Sub 25 pins, female
PC connection: Optional interface cable for RS-232C
Sampling Frequencies When not using digital output
0.72 ms/6-channel (Cutoff frequency 366 Hz)
When using digital output
22.9 ms/6-channel in binary format (Cutoff frequency 11 Hz)
45.7 ms/6-channel in ASCII format (Cutoff frequency 6 Hz)
Nonlinearity Within ±0.05% FS
Calculation Error of Compensating Interference Within ±0.1% FS
Stability Zero ±0.25 μV/V per ºC, Sensitivity ±0.01%/ºC
Functions Over input checking, automatic zero balance,
load point correction, alarm
Monitor Indicator LED Display
Alarm Output Open collector
Power Supply 100 VAC (200 VAC models are also available.)
Operating Temperature 0 to 50°C
Operating Humidity 95% RH or less (Non-condensing)
Dimensions 255 W x 88 H x 180 D mm (Excluding protrusions)
Weight Approx. 2.5 kg
Standard Accessories Output cable U-58 (6 pc)
AC power cable P-18 with conversion adapter CM-39
Optional Accessories RS cross cable N-23
Mounting fixture FL-1A

Dimensions

LAT-A

Page Top

Download