Search transducers

Selection table of Sensors or Transducers

Reset

00items were found.

Further narrow the selection range

Features

  • General purpose
  • High/low temperature
  • Absolute pressure measurement
  • Pressure transmitter
  • Differential pressure measurement
  • Distributed pressure measurement

Rated capacity

  • ≤1 Mpa
  • 2 MPa to 50 Mpa
  • ≥100 Mpa
Product image Type Description

PGL-A
Small-sized Pressure Transducer
The PGL-A is a compact & lightweight pressure transducer with the semi-flush diaphragm at the end. It is high accuracy.
Rated Capacity: 1 to 50 MPa
Compensated Temperature: -10 to 60ºC

PHL-A
Small-sized High/Low-temperature Pressure Transducer
The PHL-A is a compact & lightweight pressure transducer with the semi-flush diaphragm at the end. It is suitable for measurement under high or low temperature.
Rated Capacity: 1 to 50 MPa
Compensated Temperature: -20 to 150ºC for PHL-A-A, -196 to 200ºC for PHL-A-B
PG-U

PG-U
Pressure Transducer
The PG-U is a pressure transducer with high accuracy and reliability because of hermetically-sealed structure with inert gas filled in.
Rated Capacity: 200 kPa to 50 MPa
Compensated Temperature: -10 to 60ºC

PGS-A
Small-sized Pressure Transducer
The PGS-A is a compact & lightweight pressure transducer.
Rated Capacity: 1 to 50 MPa
Compensated Temperature: -10 to 60ºC

PG-H
Pressure Transducer
The PG-H is a pressure transducer with hermetically sealed with inert gas filled in.

Rated Capacity: 100, 200 MPa
Compensated Temperature: -10 to 70ºC
PGM-H

PGM-H
Small-sized Pressure Transducer
The PGM-H is a small-sized pressure transducer with the semi-flush diaphragm at the end.

Rated Capacity: 500 kPa to 50 MPa
Compensated Temperature: -10 to 60ºC
PGM-E

PGM-E
Small-sized Pressure Transducer
The PGM-E is a small-sized pressure transducer with the flush diaphragm at the end.

Rated Capacity: 1 to 50 MPa
Compensated Temperature: 0 to 60ºC
PGM-G

PGM-G
Low Pressure Transducer
The PGM-G is a accurate & stable pressure for measuring low pressure.
Rated Capacity: 20 to 100 kPa
Compensated Temperature: -10 to 60ºC
PGMC-A

PGMC-A
Small-sized Pressure Transducer
The PGMC-A is a compact pressure transducer with flush-diaphragm at the end.
Rated Capacity: 200 kPa to 1 MPa
Compensated Temperature: 0 to 50ºC
PGM-D

PGM-D
Small-sized Pressure Transducer
The PGM-D is a small-sized pressure transducer with the diaphragm at the end.
Rated Capacity: 5 to 50 MPa
Compensated Temperature: 0 to 60ºC

PGR-A
High-pressure-resistant Pressure Transducer
The PGR-A is a high pressure-resistant pressure transducer for measuring pressure at high temperature.
Rated Capacity: 1 MPa to 20 MPa
Compensated Temperature: -10 to 100ºC
Ultimate Overloads: 117.7 MPa for 1 MPa to 5 MPa, 196.1 MPa for 10 MPa and 20 Mpa
PAB-A

PAB-A
Absolute Pressure Transducer
The PAB-A is a absolute pressure transducer for measuring pressure from absolute zero.
Rated Capacity: 200 kPaabs. to 2 MPaabs.
Compensated Temperature: -20 to 70ºC

PHS-B
Highly Reliable Pressure Transducer (Sputter-gage Type)
The PHS-B is a absolute pressure transducer for measuring absolute pressure at high or low temperature in high reliability.

Rated Capacity: 200 kPaabs. to 20 MPaabs.
Compensated Temperature: -30 to 200ºC
PHC-B

PHC-B
Flush Diaphragm Type High-temperature Pressure Transducer
The PHC-B is a flush-diaphragm type pressure transducer for measuring pressure at high temperature. It adopt thin-film strain gage formed by sputtering.
Rated Capacity: 2 to 20 MPa
Compensated Temperature: 23 to 230ºC

PHB-A
High/Low-temperature Pressure Transducer
The PHB-A is a pressure transducer for measuring pressure at high or low temperatures. The sensing surface is a stainless steel diaphragm.
Rated Capacity: 1 to 50 MPa
Compensated Temperature: -196 to 200ºC
PHF-S-S3

PHF-S-S3 Series
Small-sized High-temperature Pressure Transducer
Excellent in environmental performance
Rated Capacity: 2 to 20 MPa
Compensated Temperature: -40 to 150°C
PGH-S-100MPSA17

PGH-S-100MPSA17
Large-capacity Pressure Transducer
The PGH-S-100MPSA17 is a large-capacity pressure transducer for measuring high pressure at high temperature up to 150ºC.

Rated Capacity: 100 MPa
Compensated Temperature: -20 to 150ºC
PGH-S-300MPSA19

PGH-S-SA19
Large-capacity Pressure Transducer
The PGH-SA19 is a pressure transducer for measuring high pressure.

Rated Capacity: 250, 300 MPa
Compensated Temperature: 0 to 60ºC

PAV-R
Voltage-output Pressure Transducer
The PAV-R is a strain-gage pressure transducer with a built-in amplifier and output voltage signals from 0 to 5V. The cable is integrated with the PAV-R. It is suitable for inductrial equipment or pressure control system.
Rated Capacity: 1 to 50 MPa
Compensated Temperature: -20 to 70ºC
PAV-U

PAV-U
Voltage-output Pressure Transducer
The PAV-U is a strain-gage pressure transducer with a built-in amplifier and output signals from 0 to 5 V. The cable can be replaced. It is suitable for inductrial equipment or pressure control system.
Rated Capacity: 1 to 50 MPa
Compensated Temperature: -20 to 70ºC
PAA-R

PAA-R
Current-output Pressure Transducer
The PAA-R is a strain-gage pressure transducer with a built-in amplifier and output signals from 4 to 20 mA. The cable is integrated with the PAA-R. It is suitable for inductrial equipment or pressure control system.
Rated Capacity: 500 kPa to 50 MPa
Compensated Temperature: -20 to 70ºC
PAA-U

PAA-U
Current-output Pressure Transducer
The PAA-U is a strain-gage pressure transducer with a built-in amplifier and output signals from 4 to 20 mA. The cable can be replaced. It is suitable for inductrial equipment or pressure control system.
Rated Capacity: 500 kPa to 50 MPa
Compensated Temperature: -20 to 70ºC
PVL

PVL
Voltage-output Pressure Transducer
The PVL is a voltage-output pressure transducer with a built-in amplifier. It is strong against noise. 2 types are available, PVL-A/B is a cable-integrated one and PVL-C/D a connector-equipped one. PVL-B/D output 0 to 5 V, and PVL-A/C output 1 to 5 V.
Rated Capacity: 500 kPa to 50 MPa
Compensated Temperature: -10 to 60ºC
PAL

PAL
Current-output Pressure Transducer
The PAL is a current-output pressure transducer with a built-in amplifier. It is strong against noise and output signals of 4 to 20 mA. 2 types are available, PAL-A is a cable-integrated one and PAL-B a connector-equipped one.
Rated Capacity: 500 kPa to 50 MPa
Compensated Temperature: -10 to 60ºC
PAG-A

PAG-2KA
Highly Stable Current-output Pressure Transducer
The PAG-A is a highly stable current-output pressure transducer and output signals from 4 to 20 mA. It is hermetically-sealed structure with inert gas filled in. The amplifier enables to provide high-frequency radio noise resistant.
Rated Capacity: 200 kPa
Compensated Temperature: -20 to 70ºC

PS-C
Miniature Pressure Sensor
The PS-C is a miniature pressure sensor with a strain-gage bridge inside. The cable direction is parallel to the sensor surface.
Rated Capacity: 50 kPa to 7 MPa
Compensated Temperature: 0 to 50ºC

PS-D
Miniature Pressure Sensor
The PS-D is a miniature pressure sensor with a strain-gage bridge inside. The cable direction is at right angle to the sensor surface.
Rated Capacity: 50 kPa to 7 MPa
Compensated Temperature: 0 to 50ºC
PSS

PSS
Miniature Pressure Sensor
The PSS is a miniature pressure sensor with a strain-gage bridge inside. Thin-film strain gages are directly formed on the diaphragm.
Rated Capacity: 20, 50, 100 kPa
Compensated Temperature: 0 to 50ºC (As for PSS-AF/BF, Non-condensing)

PSM-AB
Miniature Pressure Sensor
The PSM-AB is a miniature pressure sensor with a flurocarbon resin cable. It adopts quarter-bridge 3-wire mode and configures a full bridge by a bridge adapter.
Rated Capacity: 100, 200 kPa
Compensated Temperature: 0 to 50ºC
PDS-A

PDS-A
Minute Differential Pressure Transducer
The PDS-A is a minute differential pressure transducer with diffusional semiconductor strain gages on a silicon diaphragm. It is suitable for wind-pressure measurement.

Rated Capacity: 1 to 7 kPa
Compensated Temperature: 0 to 50ºC
PD-A

PD-A
Differential Pressure Transducer
The PD-A is a differential pressure transducer for accurate measuring slight differential pressures. The max line pressure is 2.94 MPa. It can be used not only for differential pressure measurement, but also flow rate measurement.
Rated Capacity: 10 to 200 kPa
Compensated Temperature: 0 to 60ºC

PDV-A
Minute Differential Pressure Transducer
Minute Differential Pressure Transducer PDV-A has diffusional semiconductor strain gages on a silicon diaphragm.
It is suitable for wind-pressure measurement.

Rated Capacity: 1 to 7 kPa
PDU-A

PDU-A
Stainless Steel Differential Pressure Transducer
The PDU-A is a stainless steel differential pressure transducer for measuring differential pressure under line pressure of max 30 MPa. It has a built-in variable damping mechanism.
Rated Capacity: 50 kPa to 2 MPa

PE-30KF
Engine Pressure Transducer
For measuring exhaust or inlet pressure

Rated Capacity: 3 MPa
Safe Temperature:
 Attaching screw section: Max. 300°C
 Wastewater: Max. 80°C