DCS-100A
Dynamic Data Acquisition Software

DCS-100A

Summary

Monitors measurement data with various graphs and numerical windows.
Acquires data efficiently.

The software enables easy interactive setting of various conditions and facilitates efficient acquisition of required data by showing variables under measurement in graphs and numeric windows on the display.
Measuring instruments are EDS-400A, EDX-10 series, EDX-100A, EDX-200A, EDX-5000A, PCD-400A, PCD-430A, UCAM-550A, NTB-500A, and CTRS-100 series.

Features

●The basic operation does not depend on the controlled measuring instrument, so even if the
measuring instrument been changed, the DCS-100A is still user-friendly.
●Y-time, X-Y, bar graphs, circular meters, and numeric display are possible.
●Measuring condition setting, data acquisition, data collection, data reproduction and file conversion. For analyzing the acquired data, an optional data analysis software DAS-200A is recommended.
●Acquires large capacity data by PC's hard disk.
●Collects data automatically.
●Easy operation with the toolbar, function keys and operation panel
●Converts Kyowa standard data file format (KS2) into CSV and Exccel formats during data reproduction.

Products table

All display

DCS-100A
Dynamic Data Acquisition Software

DCS-100A

Common specifications

Operating Environment
OS Windows® 7, Windows® 8.1 or Windows® 10
Japanese/English
32, 64 bits support
If 64-bit OS, operate in WOW64 (Windows 32-bit On Windows 64-bit) environment.
CPU Corei5  2 GHz or advanced
Memory If 32-bit OS, 2 GB or more
If 64-bit OS, 4 GB or more
Display 1024×768 pixels or more
Monitor Display
Y-time Graphs Allows up to 16 channels of physical quantities to be graphed on Y axis with X axis for time.
1 to 10 graphs per window
Y-time (All channels) Graphs Allows all channels of physical quantities to be graphed on Y axis with X axis for time in the same color curves.
Y-time (DIV) Graphs Allows up to 16 channels of physical quantities to be graphed on Y axis with X axis for time.
Zero point of each channel is moved freely to a desired position on a division of axis.
X-Y Graphs Variables of desired 8 channels each for both X axis and Y axis are graphed in free combination.
Bar Graphs One bar graph has up to 32 channels and 1 to 4 graphs per window.
Peak hold ON or OFF is possible.
(Capable of displaying peak values.)
Circular Meters Variable of 1 desired channel per circular meter
Bar Meters Variable of 1 desired channel per horizontal or vertical bar meter
Numeric Windows Shows numeric data of desired 1 or 16 channels or all channels. (Capable of displaying max. and min. values of every channel)
Over Input Indication Capable of displaying the excessive channel values in red.
Graph Scale Capable of displaying auto-scale and full scale values on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph (Y axis).
The Y-time graph (Y axis) is able to change to 1 axis, 2 axes, or channel.
Display Color Freely changeable graph by graph
Titles and Labels Sets a desired title and labels for X and Y axes.
Number of Simultaneously Displayed Windows 32 numeric windows and 32 graph windows.
64 in total. (Including reproduced data windows.)
*However that the number of windows may be restricted by the CPU speed and memory of the PC.
Auxiliary Lines Capable of displaying the desired auxiliary lines on the Y-time Graphs (X axis and Y axis), X-Y Graphs (X axis and Y axis), and Bar Graphs (X axis and Y axis).
(Up to 4 auxiliary lines each for both X axis and Y axis.)
Comparative Data Displays the comparative data (Previous KS2 format file) on the Y-time graphs, excluding the Y-time (All channels) graphs and Y-time (DIV) graphs, and X-Y graphs for comparing the monitor data.
The size of the data file is maximum 10 MB.
If the file size exceeds 10 MB, the DCS-100A displays the 10 MB data from its head.
Dual-display Capable of moving the numeric windows or graph windows onto the sub display
Channel Conditions & Measuring Conditions
Setting Ranges Applied recorder is set according to the specifications.
TEDS Information Reading sensor's TEDS information and setting to channel conditions automatically
(TEDS sensor only)
Saving and Loading Measurement Condition File Capable of saving and loading the sensor information file (CSV format file) on the channel conditions.
Data Reproduction
Y-time Graphs Allows up to 16 channels of physical quantities to be graphed on Y axis with X axis for time.
1 to 10 graphs per window.
Y-time (DIV) Graphs Allows up to 16 channels of physical quantities to be graphed on Y axis with X axis for time.
Zero point of each channel is moved freely to a desired position on a division of Y axis.
X-Y Graphs Variables of desired 8 channels each for both X axis and Y axis are graphed in free combination.
Numeric Windows Shows numeric data in a list.
Graph Scale Capable of displaying auto-scale and full scale values on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph (Y axis). The Y-time graph (Y axis) is able to change to 1 axis, 2 axes, or channel.
Display Color Freely changeable graph by graph
Titles and Labels Sets a desired title and labels for X and Y axes.
Number of Simultaneously Displayed Windows 32 numeric windows and 32 graph windows.
64 in total. (Including reproduced data windows.)
*However that the number of windows may be restricted by the CPU speed and memory of the PC.
Size of Data Files Available on a Single Screen Size of the data file displayed at a time on graph and numeric windows is maximum 10 MB. If the file size exceeds 10 MB, 10 MB data of a desired portion is displayed by setting the range.
File Conversion Desired range or data of a desired channel is extracted and converted to CSV, XLS, XLSX, or RPCⅢ format file.
Auxiliary Lines Capable of displaying the desired auxiliary lines on the Y-time Graphs (X axis and Y axis), X-Y Graphs (X axis and Y axis), and Bar Graphs (X axis and Y axis).
(Up to 4 auxiliary lines each for both X axis and Y axis.)
Max., Min., and Average Capable of displaying the maximum value/minimum value/average value within the window on the Y-time Graphs.
(Capable of displaying the maximum value/minimum value/average value when the number of channels is 1 or 2.)
Dual-display Capable of moving the Numeric windows or Graph windows onto the sub display.
Setting Environment
Data File Destinations Measured data is saved in storage media of the controlled recorder. Also possible is direct saving in the hard disk of PC, while it is limited by the sampling frequency and the number of measuring channels.
Automatic Transfer of Data Files Data files are automatically transferred to the hard disk of PC upon completion of recording.
Automatic Conversion Data files are automatically converted to format of CSV, XLS, XLSX, or RPCⅢ, upon completion of recording.
Optional Units Registers up to 3 user-defined units.
PAUSE Function While Recording Data PAUSE function ON or OFF is possible.
Data Files
Saving Formats Kyowa standard file format (KS2)
File Coupling Data files saved in controlled recorders operated in synchronization are combined to a single data file at the time of collection by the PC.

EDS-400A Control Specifications

Controllable Units 8 (Max. 32)
Interfaces LAN
Data Storage Measured data is saved to CF card in the EDS and/or data folder in the PC in KS2 format.
Channel Conditions Measuring channel, measuring mode (strain/voltage), range, zero suppression ON/OFF, test ON/OFF, calibration coefficient, offset, unit, channel name, measuring range, rated capacity, rated output,
Deci Digits (Selection of any display item is possible.)
Setting/Loading Parameters Sets and loads the EDS internal parameters.
Collecting Data Collects KS2 files saved in the CF card in the EDS via LAN or CF card in the PC.
Erasing Data Erases KS2 files in the CF card in the EDS via LAN.
Environmental Settings
Hardware Configuration Setting of connected units and device name
Reading of hardware configuration from EDS-400A.
Communication Status Checked by reading the version of the EDS
IP Address Settable, from the PC via LAN. It is saved in CF card.
Measuring Conditions for Saving Data in CF Card
Sampling Frequencies 1 Hz to 100 k Hz (Depends on the number of measuring channels)
Data File Size Max. 2 GB (Depends on the number of measuring channels)
Measuring Modes Manual, analog trigger, and external trigger
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Trigger Measurement Start/stop recording based upon specified trigger conditions.
Trigger Conditions
 End Trigger Settable
 Delay Max. 2000 data points
(The delay time varies with the number of channels.)
 Trigger Channels Any 1 channel
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down or both
Measuring Conditions for Saving Data in PC Hard Disk
Sampling Frequencies 1 Hz to 10 kHz
Data Files Size Capacity of the hard disk
Measuring Modes Manual, interval, and analog trigger
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
Analog Trigger Measurement Start/stop recording based upon specified trigger conditions.
Trigger Conditions
 End Trigger Settable
 Delay Max. 32000 data points
(The delay time varies with the number of channels.)
 Trigger Channels Any 1 channel
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down or both

EDX-100A Control specifications

Controllable Units 8 (Max. 256 channels)
Interfaces LAN, USB
Data Storage Measured data is saved to CF card in the EDX and/or data folder in the PC in KS2 format.
Channel Conditions Measuring channel, measuring mode, range, HPF, LPF, balance ON/OFF, CAL range, CAL ON/OFF, calibration coefficient, offset, unit, channel name, measuring range, rated capacity, rated output, Deci Digits, internal sensitivity compensation ON/OFF, offset, ZERO ON/OFF (Selection of any display item is possible.)
TEDS Reads sensor's information and sets to channel condition automatically.
Collecting Data Collects data saved in the CF card in the EDX via LAN or USB or directly insert the CF card in the PC.
Erasing Data Erases data via LAN or USB in on-line or off-line
Setting/Loading Parameters Sets and loads the EDX-100A internal parameters.
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
Trigger Measurement Start/stop recording based upon specified trigger conditions.
End Trigger Settable
Delay For both start and end, max. 262144 values.
The delay time varies with the number of channels.
Measuring Conditions for Saving Data in CF Card
Data File Size Max. 2 GB
External Trigger Trigger slope Up, down
Composite Trigger
 Trigger Source Selectable from 2 desired channels of stand-alone or host unit, and 1 from external trigger.
 AND or OR Trigger channel and external trigger can be logically determined.
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down
Measuring Conditions for Saving Data in PC Hard Disk
Data Files Size Capacity of the hard disk
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file in manual and interval modes.
Repetition Acquisition In long-term data acquisition, a specified amount of data (or time) is saved in KS2 file .
*Workable in manual mode (Data points preset).

EDX-10 series Control specifications

Controllable Units Max. 4 (Max. 16 channels)
Interfaces USB
Data Storage Measured data is saved to data folder in the PC in KS2 format.
Channel Conditions Measurement ON/OFF, mode, range, LPF, balance, calibration coefficient, offset, unit, channel name, measuring range, rated capacity, rated output, Deci Digits, chk.val.(Up), chk.val. (Down)
(Selection of any display item is possible.)
Sampling Frequencies 1 Hz to 20 kHz (1-2-5 series)
(Depends on the number of measuring channels)
Measuring Modes Manual, manual (Data points preset), interval, and analog trigger
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
Analog Trigger Measurement Start/stop recording based upon specified trigger conditions.
 End Trigger Settable
 Delay For both start and end, max. 262144 data/channel.
*The delay time varies with the number of channels.
 Trigger Channels Any 1 channel
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file in manual and interval modes.
Repetition Acquisition In long-term data acquisition, a specified amount of data (or time) is saved in KS2 file.
*Workable in manual mode (Data points preset).
Environmental Settings
 Hardware Configuration Setting of device name and measuring unit
Configuration of device names connected to EDX-10B.
Reading of hardware configuration from EDX-10B.

EDX-200A Control specifications

Controllable Units Max. 8 (Max. 256 channels)
Interfaces LAN, USB
Data Storage Measured data is saved to CF card in the EDX and/or data folder in the PC in KS2 format.
Channel Conditions Measurement ON/OFF, mode, range, LPF, HPF, balance ON/OFF, CAL range, CAL ON/OFF, calibration coefficient, offset, unit, channel name, measuring range, Deci Digits,,rated capacity, rated output, chk.val.(Up), chk.val. (Down), internal sensitivity compensation ON/OFF, offset ZERO ON/OFF, digital filter, sampling frequency (Select dual sampling high-speed, low-speed, high-speed + low-speed)
(Selection of any display item is possible.)
Applicable Optional Cards ECAN-40A
 CAN Data Acquisition (*1) 
 DIO Setting (*3)

ETIM-40A
 Interval Measurement (GPS in sync) (*1), (*2)
 Point Zero Measurement (Manual) (*1), (*2)
 GPS Data Acquisition (*1), (*2)
 DIO Setting (*3)

EGPC-40A
 CAN Data Acquisition (*1) 
 Interval Measurement (GPS in sync) (*1), (*2)
 Point Zero Measurement (Manual) (*1), (*2)
 GPS Data Acquisition (*1), (*2)
 DIO Setting (*3)

*1: When data is saved in CF card
*2: When the card is installed in host EDX
*3: When control signals are from a remote control unit
 A. Data is saved in the CF card.
 B. If synchronous operation, only host EDX is settable.
CAN Data Acquisition Max. 512 channels/unit of CAN data is possible.
(CAN data is saved to CF card in the EDX-200A.)
Point Zero Manual Measurement In multiple units of EDX-200A, allows acquisition to be started at zero second (0 ms) based on clock data of GPS satellite.
GPS Synchronous Interval Measurement Allows multiple units of EDX-200A to be started acquisition based on clock data of GPS satellite.
GPS Data Acquisition Monitors and records GPS data such as latitude, longitude, directions of movement, speed
GPS data is saved to CF card in EDX-200A as NMEA format.
DIO Settings
 I/O Points Max. 8
 I/O Settings Sets every bit of digital input, digital output, and remote-control input.
Measuring Conditions for Saving Data to CF Card
Sampling Frequencies 1 Hz to 100 kHz
(1-2-5 series, 2n series, or external clock)
(Depends on measuring channels. Dual sampling is supported.)
Data Files Size Max. 4 GB
 Measuring Modes Manual, manual (Data point preset), interval, analog trigger, external trigger, and composite trigger
 Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
 Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
 Trigger Measurement Start/stop recording based upon specified trigger conditions. (The trigger standard values are set absolute triggers.)
 End Trigger Settable
 Delay For both start and end, max. 262144 data/channel.
(The delay time varies with the number of channels.)
Analog Trigger
 Trigger Channels Any channel
 Trigger Level Sets in physical quantity.
  Trigger Slope Up, down
 External Trigger Conditions
  Trigger Slope Up, down
 Composite Trigger Conditions
  Trigger Source Selects from analog channels (Host EDX any 4 channels), external trigger, or manual trigger.
  AND or OR Trigger source can be logically determined.
  Trigger Level Sets in physical quantity.
 Trigger Slope Up, down
Repetition Acquisition In long-term data acquisition, a specified amount of data (or time) is saved in KS2 file .
*Workable in manual mode (Data points preset).
Measuring Conditions for Saving Data in PC Hard Disk
Sampling Frequencies 1 Hz to 100 kHz (1-2-5 series, 2n series, or external clock)
Data Files Size Capacity of the hard disk
Measuring Modes Manual, manual (Data points preset), interval,
and analog trigger
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file in manual and interval modes.
Repetition Acquisition In long-term data acquisition, a specified amount of data (or time) is saved in KS2 file.
*Workable in manual mode (Data points preset).

NTB-500A Control specifications

Controllable Units Max. 8 (Max. 64 channels)
Interfaces CAN, a specified USB/CAN converter (Kvaser LEAFLIGHT HS V2) is required.
Data Storage Measured data is saved to data folder in the PC in KS2 format.
Channel Conditions Mode, range, zero, calibration coefficient, offset, units, measurement ON/OFF, decimal point,chk. val. (Up), chk. val. (Down), channel name, measuring range, rated capacity, rated output
(Selection of any display item is possible.)
Sampling Frequencies 1 Hz to 1 kHz
(Depends on the number of measuring channels and the cable length)
Measuring Modes Manual, manual (Preset data points), interval, and analog trigger
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
(No. of steps: 5; the interval can be changed at each step)
Analog Trigger Measurement Start/stop recording based upon specified trigger conditions.
 End Trigger Settable
 Delay For both start and end, max. 262144 points/channel.
*The delay time varies with the number of channels.
 Trigger Channels Any 1 channel
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down
TEDS Reads sensor's information and sets to channel condition automatically.
Changing Stroke Changes the data before the stroke and after the stroke, when using a displacement transducer.
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file in manual and interval modes.
Repetition Acquisition In long-term data acquisition, a specified amount of data (Or time) is saved in KS2 file.
*Workable in manual mode (Data points preset).
Setting/Loading Parameters Sets and loads the NTB-500A internal parameters.
Environment Settings
Hardware Configuration Setting of connected units, communications cable length, device name, measuring unit settings
Reading of hardware configuration from NTB-500A.

UCAM-550A Control specifications

Controllable Units Max. 6 (Max. 300 channels)
Max. 20 (Max.1000 channels), optional software DCS-106 is required.
Interfaces LAN
Data Storage Measured data is saved to data folder in the PC in KS2 format.
Sampling Frequencies 1, 2, 10, 20, and 50 Hz
Measuring Modes Manual, manual (Preset data points), interval, and analog trigger
Measuring Function Measure: Measured value = Sensor output value - Initial value
Original: Measured value = Sensor output value
Calibration Factor Calculation ON/OFF setting in all channels of one batch
Calibration factor compensation: Measured value x Calibration factor + Offset
Channel Conditions Measurement, mode, range, calibration factor, offset, unit, initial value, channel name, measuring range, Deci Digits, chk. val. (Up), chk. val. (Down), rated capacity, rated output
(Selection of any display item is possible.)
Initial Value Measurement Measures the initial value of each sensor.
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
Analog Trigger Measurement Start/stop recording based upon specified trigger conditions.
Analog Trigger Conditions
 End Trigger Settable
 Delay For both start and end, max. 3000 points/channel.
 Trigger Channels Any 1 channel
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down
Changing Stroke Changes the data, before the stroke and after the stroke, when using a displacement transducer.
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file in manual and interval modes.
Burnout Check For USM-51B/52B only
TEDS Reads sensor's information and sets to channel condition automatically.
(USM-51B/52B only)
Setting/Loading Parameters Sets and loads the UCAM-550A internal parameters.
Environmental Settings
 Hardware Configuration Setting of connected units, device name, setting for IP address
Reading of hardware configuration from UCAM-550A.
Communication Status Checked by reading the version of the UCAM

PCD-400A PCD-430A Control specifications

Controllable Units Max. 4 (Max. 16 channels)
Interfaces USB
Data Storage Measured data is saved to data folder in the PC (in KS2 format).
Channel Conditions Measurement ON/OFF, strain mode, range, LPF, balance ON/OFF, calibration coefficient, offset, gage factor, unit, channel name, measuring range, Deci Digits, rated capacity, rated output, upper limit check, lower limit check, offset zero ON/OFF
(Any display item is selectable)
Sampling Frequencies 1 Hz to 10 kHz (1-2-5 series)
Measuring Modes Manual, manual (Preset data points), interval, and analog trigger
Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or by completion of recording using a preset number of measurements.
Interval Measurement Measurement is made automatically at preset intervals from the preset starting time.
Analog Trigger Measurement Start/stop recording based upon specified trigger conditions.
Trigger Conditions
 End Trigger Settable
 Delay For both start and end, max. 640000 data / channel.
 Trigger Channels Any 1 channel
 Trigger Level Sets in physical quantity.
 Trigger Slope Up, down
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file in manual and interval modes.
Repetition Acquisition In long-term data acquisition, a specified amount of data is saved in KS2 file at specified intervals.
*Workable in manual mode (Data points preset).
Hardware Configuration Unit name settings possible on the PCD-400A/430A
Number of connected units readable from the PCD-400A/430A
Automatic Data File Conversion Automatic file conversion upon the termination of measurement
(CSV, XLS, XLSX, and RPC Ⅲ formats)
Arbitrary Unit Settings Up to 3 user's units of measurement are settable

CTRS-100A Control specifications

Number of Units Up to 4 units (up to 128 analog channels.)
Applicable Unit Measure unit: CTRS-CDV010A
Expansion unit: CTRS-BATT010A, CTRS-SYNC010A
Interface USB (USB2.0 High Speed) or Ethernet* (10/100BASE-T)
*A separate synchronous unit and special communication cable are necessary.
Saving Format Saves the measured data in the CTRS-100A SD card or PC folder.
When saving to the SD card of CTRS-100A, save the KS3 file to the SD card of CTRS-100A
Save and convert to a KS2 file (01.06) when retrieving the PC.
When saving to PC folder, save as KS2 file (01.06).
Channel Conditions Measuring ON/OFF, Measuring mode, Range (Arbitrary input), High-pass filter, Low-pass filter, Balance adjustment ON/OFF/NONE, Input resistance check ON/OFF, Calibr. const., Offset, Cable correction value, Offset ZERO Value, Unit, Channel name, Measuring range, Rated capacity, Rated output, Deci Digits, Chk. Val. (Up), Chk. Val. (Down), Offset ZERO ON/OFF, TEDS User Data, TEDS Sensor Model, TEDS Sensor S/N, TEDS ROMID
(Display items can freely be selected.)
Loading TEDS Sensor Information Loads the TEDS information automatically and sets the channel conditions.
Setting Parameter and Loading Parameter Loads and sets the CTRS-100A internal parameter.
Saving and Loading Meas Condition File Loads and saves the meas condition file. (Extension: C1H)
The meas condition file includes environment settings, channel conditions, measuring conditions, display conditions on graphs and on numeric windows, and arithmetic operation conditions (optional).
Saving and Loading CTRS-100A Condition File Loads and saves the CTRS-100A condition file (Extension: SET) by using the SD card.
Collecting Data File Convert KS3 files in CTRS-100A SD card to KS2 files and recover.
Deleting Data File PC deletes the file (KS3), saved in the CTRS-100A SD card.
Formatting SD Card PC formats the CTRS-100A SD card.
Setting Environment
 Setting Hardware Configuration Sets Interface, the number of units and device names.
Loads the hardware configurations from the CTRS-100A.
 Communication Check Loads the CTRS-100A version.
 Device Confirmation LEDs, on the CTRS-100A front panel, light up.
 Others Remote control unit operation beep, balance standard value, PAUSE ON/OFF, detailed hardware information display
When Saving the Measured Data in the CTRS-100A SD Card
Sampling Frequency 1 Hz to 100k Hz (1/2/5 system, 2n system, external clock)
*Limited by the number of channels.
Number of Data/CH Up to 1,000,000,000 data
Measure Mode Manual, Manual (Set Record Data), Interval, Analog Trigger, External Trigger, Manual Trigger, Complex Trigger
Manual Measurement Records data from REC to STOP or from REC to the number of data, specified on the Manual (Set Record Data).
Recording start time: Settable
Interval Measurement Records data automatically based on the pre-set starting time and recording interval.
Trigger Measurement Starts/stops recording data based on the pre-set trigger conditions.
Common Trigger Conditions End trigger: Settable

Delay: Up to 524,288 data for both start and end.
   The delay time varies with the number of channels.
Analog Trigger Conditions Trigger channel: Any 1 channel of the master unit

Trigger level: Physical quantity

Trigger slope: Positive or Negative
External Trigger Conditions Trigger slope: Positive or Negative
Manual Trigger Conditions
Complex Trigger Conditions Trigger source: Select from the analog channels (any 4 channels of the master unit), external trigger, or manual trigger.
Capable of judging the trigger source by using the logical AND and OR operators.

Trigger level: Physical quantity

Trigger slope: Positive or Negative
Repeated Recording When recording data for a long time, the DCS-100A saves data, every pre-set number of data or every pre-set interval, in the KS3 format file.
*Measure Mode: Manual (Set Record Data) only.
Data File File name, File Title, Grant rule: File No or Recording start time
File No: 3 to 5 digits.
When Saving the Measured Data in the PC Folder
Sampling Frequency 1 Hz to 100k Hz (1/2/5 system, 2n system, external clock)
*Limited by the number of channels.
File Size Up to the data drive capacity.
Measure Mode Manual, Manual (Set Record Data), Interval, Analog Trigger
Manual Measurement Records data from REC to STOP or from REC to the number of data, specified on the Manual (Set Record Data).
Interval Measurement Records data automatically based on the pre-set starting time and recording interval.
Analog Trigger Measurement Starts/stops recording data based on the pre-set trigger conditions.

End trigger: Settable

Delay: Up to 524,288 data for both start and end.
   The delay time varies with the number of channels.

Trigger channel: Any 1 channel

Trigger level: Physical quantity

Trigger slope: Positive or Negative
Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the moving-averaged measured data in a single CSV format file.
*Measure Mode: Manual and Interval only.
Repeated Recording When recording data for a long time, the DCS-100A saves data, every pre-set number of data or every pre-set interval, in the KS2 format file.
*Measure Mode: Manual (Set Record Data) only.
Data File File name, File Title, Grant rule: File No only
File No: 4 digits only.

DCS-101A
Simultaneous Acquisition of Video and Numeric Data/Arithmetic Operations/FFT Analysis Optional Software

DCS-101A

Specifications

Operating Environment
OS Windows® 7, Windows® 8.1 or Windows® 10
English/Japanese
32, 64 bits support
If 64-bit OS, operate in WOW64 (Windows 32-bit On Windows 64-bit) environment.
CPU Corei5 2 GHz or advanced
* Corei5 3 GHz or advanced CPU is required for recording video, performing arithmetic operations, and FFT analysis simultaneously.
Memory If 32-bit OS, 2 GB or more
If 64-bit OS, 4 GB or more
Display 1024x768 pixels or more
Video Data Acquisition
Applicable Cameras DirectX-compatible web cameras
(A web camera which the OS can recognizes as an imaging device)
Number of Applicable Cameras 1
Resolution 640×480 pixels or more
Frame Rate Max. 30 frames per second
Saving File Formats AVI (Audio-Video Interleave)
Number of Video Capture Windows 1
Operations Video data monitoring/recording in linkage with measuring operation
Zooming
*Resolution and frame rate depend on an applied camera.
Measuring Conditions for Video Acquisition
Applicable Instruments EDS-400A, PCD-400A/430A, EDX-10B, EDX-100A, EDX-200A, UCAM-550A, NTB-500A, EDX-5000A and CTRS-100A
Measuring Modes Saved in the PC:
Manual, manual (Data points preset)

Saved in the measuring instrument:
Manual, manual (Data points preset), trigger
Video Playback
File Formats AVI
Number of Playback Files 1
Number of Playback Windows 1
Operations Play, stop, pause, frame-by-frame forward, backward, zoom, change of reproduce speed
Synchronized Cursors Allows video and graphs to be reproduced with the synchronized cursors
Arithmetic Operations
Number of Calculation Channels Max. 32
*Up to 64 (EDX-5000A)
Calculation Channel Conditions Calculation ON or OFF, arithmetic expression (within 200 characters), unit, number of numeric digits on display, channel name (within 40 characters)
Printout Preview and printout of calculation channel conditions possible
Reading & Saving Calculated channel conditions are read and saved as a file of calculated channel condition file. Matrix conditions are read and saved as a condition file (CSV format)
Operations Calculating channel data is monitored together with measuring data and saved in the same data file.
Arithmetic Expression
Applicable Channels Measuring channels, calculation channels
Operators and Constants +,-,*,/,^《 power》,PI[ π],( )[parentheses]
Function SQR: Square root
ABS: Absolute value
SIN: Sine
COS: Cosine
TAN: Tangent
ASIN: Arc sine (Return value: Radian)
ACOS: Arc cosine (Return value: Radian)
ATAN: Arc tangent (Return value: Radian)
DSIN: Arc sine (Return value: Angle)
DCOS: Arc cosine (Return value: Angle)
DTAN: Arc tangent (Return value: Angle)
LOG: Common logarithm
LN: Natural logarithm
EXP: Exponent
HMX : Max. principal strain
HMN: Min. principal strain
HSM: Max. shearing strain
SMX : Max. principal stress
SMN: Min. principal stress
SSM: Max. shearing stress
DEG: Principal strain direction
Measuring Conditions for Arithmetic Operations
Applicable Instruments EDX-100A, EDX-200A, EDX-10B, EDS-400A, UCAM-550A, NTB-500A, PCD-400A/430A, EDX-5000A, CTRS-100A
Data Save Folders PC data file folders
*Saves in the EDX-5000A data drive.
Measuring Modes Manual, manual (Data points preset)
interval, and analog trigger
Sampling Frequencies Max. 10 kHz
*Measuring conditions differ with measuring instruments.
Others Arithmetic operations are not available when measuring the CAN data with the EDX-100A/EDX-200A.
FFT Analysis
Analysis Types Linear spectrum, power spectrum, cross-spectrum, auto-correlation, and cross-correlation
Number of Analytical Data 256, 512, 1024, 2048, 4096, and 8192
Window Functions OFF, Hamming, Hanning, Fejer, Blackman, and Gaussian
Number of Analytical Result Windows Max. 8
Image Display of Analytical Results Types             Graph
Linear Spectrum    Amplitude (Linear or log), phase
Power Spectrum    Amplitude (Linear or log)
Cross Spectrum    Amplitude (Linear or log), phase
Auto-correlation    Correlation
Cross-correlation   Correlation
Saving The analysis results are saved as DAS-200A FFT analysis files (CSV format).
Applicable Instruments EDX-100A, EDX-200A, EDX-10B, EDS-400A, NTB-500A, PCD-400A/430A, EDX-5000A, CTRS-100A
*Measuring conditions differ with measuring instruments.

DCS-104A
GPS Data Acquisition Optional Software

DCS-104A

Specifications

Operating Environment
OS Windows Vista®, Windows® 7, Windows® 8, 8.1 or Windows® 10, English/Japanese
32, 64 bits support
CPU Core2Duo, 2 GHz or advanced
Memory If 32-bit OS, 2 GB or more
If 64-bit OS, 4 GB or more
Display 1024 x 768 pixels or more
GPS Data Acquisition
GPS Data Display During monitoring and acquisition,arbitrary selection of latitude, longitude,direction of movement, speed, reception status,and number of received satellites for display is possible.
GPS Data Files Formats NMEA-0183 (Extension: NMEA)
In the same folder as the acquisition data KS2 files, these are saved as a separate file with the same name as the KS2 file.
Applicable GPS Receivers
Interface RS-232C or USB connection (If USB connection, then a USB-to-serial port converter driver enables equivalent RC-232C connection)
If the PC does not have a COM port, then to connect using RS-232C, use a RS-USB conversation adapter.
Output Format NMEA-0183
Geographical Coordinates WGS-84
Connected Units 1
Models Confirmed to Operate HOLUX Comet USB/3XHL
SanJose Antares 48USB/UBX5
Measuring Conditions
Applicable Instruments PCD-400A/430A, EDS-400A, EDX-10B,EDX-100A, EDX-200A
Measuring Modes Saved in the PC:Manual, manual (Data points preset)
Saved in the measuring instrument:Manual, manual (Data points preset), trigger
*Measuring conditions differ with measuring instruments.

DCS-105A
CANdb file read optional software

DCS-105A

Specifications

Operating Environment
OS Windows Vista®, Windows® 7, Windows® 8, 8.1 or Windows® 10, English/Japanese
32, 64 bits support
CPU Core2Duo, 2 GHz or advanced
Memory If 32-bit OS, 2 GB or more
If 64-bit OS, 4 GB or more
Display 1024 x 768 pixels or more
Applicable Instruments EDX-100A, EDX-200A
CANdb File Read Sets CAN condition of DCS-100A by reading CANdb file.
Applicable Conditioner Cards CAN-41A
Applicable Card for Optional Slot ECAN-40A (EDX-200A optional card)
EGPC-40A (EDX-200A optional card)

DCS-106A
1000-channel for UCAM-550A Optional Software

DCS-106A

Specifications

Operating Environment
Applicable Instruments UCAM-550A
OS Windows Vista®, Windows® 7, Windows® 8, 8.1 or Windows® 10, English/Japanese
32, 64 bits support
CPU Intel Core i5 2.6 GHz or advanced
Memory If OS is 32-bit OS, 2 GB or more
If OS is 64-bit OS, 4 GB or more
Display 1024 x 768 pixels or more
Number of Acquisition Channels Enables UCAM-550A (20 units) to perform measurement in 1000 channels.

Page Top