Adhesives and Bonding Tools

Operating temperature range
- High temperature
- Normal to Mid/High Temperature
- Ultra low
Curing
- Cured at normal temperature
- Cured by heating
Result of narrowing
00items were found.
Products table
All display
CC-33A
Instantaneous adhesive cured at normal temperature

Models | CC-33A:2g×1 CC-33AX5:2g×5 |
---|
Specifications
Types | Instantaneous adhesive cured at normal temperature |
---|---|
Operating Temperature (℃) | -196 to 120 (Regular temperature: 20 to 80) |
Major Applicable Materials | ・Metals (Steel, stainless steel, copper, aluminum alloys A1050, A2024, etc.) ・Plastics (Acrylate, PVC, nylon, etc.) ・Composite materials (CFRP, GFRP, PCB, etc.) ・Rubber |
Curing Requirements | Apply finger pressure (100 to 300 kPa) for 15 to 60seconds. (After curing, leave the gage for 1 hour or more.) *The finger pressure application time differs depending on temperature and humidity conditions. The lower the temperature and humidity, the longer the finger pressure application time required. |
Category | 1 type of cyanoacrylate liquid |
Capacity | CC-33A:2g×1 CC-33AX5:2g×5 |
Features | • Suitable for bonding general-purpose gages which are used for general stress measurement at normal temperature. • Quick curing ensures smooth bonding workability. • Enables measurement in approximately 1 hour from bonding. |
Major Applicable Gages | KFGS, KFGT, KFRB, KFWB, KFWS, KFRPB, KFRS, KFP, KSPB, KSNB (Excl. E5), KSPH, KSPLB, KFLB, KFNB, KFSB, KFF, KCH, KV |
CC-35
Instantaneous adhesive cured at normal temperature

Models | CC-35:2g×1 CC-35X5:2g×5 |
---|
Specifications
Types | Instantaneous adhesive cured at normal temperature |
---|---|
Operating Temperature (℃) | -30 to 120 (Regular temperature: 20 to 80) |
Major Applicable Materials | ・Concrete ・Mortar ・Wood |
Curing Requirements | Apply finger pressure (100 to 300 kPa) for 30 to 60seconds. (After curing, leave the gage for 1 hour or more.) *The finger pressure application time differs depending on temperature and humidity conditions. The lower the temperature and humidity, the longer the finger pressure application time required. |
Category | 1 type of cyanoacrylate liquid |
Capacity | CC-35:2g×1 CC-35X5:2g×5 |
Features | ●High viscosity makes it suitable for bonding to porous materials such as lumber and concrete. ●Suitable for bonding general-purpose gages which are used for general stress measurement at normal temperature. |
Major Applicable Gages | KFGS, KFGT, KFRB, KC, KFRPB, KFP |
CC-36
Instantaneous adhesive cured at normal temperature

Models | CC-36:2g×1 CC-36X5:2g×5 |
---|
Specifications
Types | Instantaneous adhesive cured at normal temperature |
---|---|
Operating Temperature (℃) | -30 to 100 (Regular temperature: 20 to 80) |
Major Applicable Materials | ●Metals (Steel, stainless steel, copper, aluminum alloys A1050, A2024, A7075, magnesium alloy, etc.) ●Plastics (Acrylate, PVC, nylon, polypropylene, etc.) ●Composite materials (CFRP, GFRP, PCB, etc.) ●Concrete ●Mortar ●Wood ●Rubber |
Curing Requirements | Apply finger pressure (100 to 300 kPa) for 30 to 180 seconds. (After curing, leave the gage for 1 hour or more.) *The finger pressure application time differs depending on temperature and humidity conditions. The lower the temperature and humidity, the longer the finger pressure application time required. |
Category | 1 type of cyanoacrylate liquid |
Capacity | CC-36:2g×1 CC-36X5:2g×5 |
Features | ●Suitable for bonding a high-elongation gage (such as KFEM and KFEL) at normal temperature. ●Suitable for bonding to non-adhesive materials such as aluminum alloy (A7075) and magnesium alloy. ●High peeling resistance, high impact resistance and less aging deterioration of bonding strength |
Major Applicable Gages | KFEM, KFEL, KFGS, KFGT, KFRB, KFWB, KFWS, KFRPB, KFRS, KFP, KSPB, KSNB (Excl. E5), KSPH, KSPLB, KFF, KV |
EP-270
Cured at normal temperature

Specifications
Types | Cured at normal temperature |
---|---|
Operating Temperature (℃) | -269 to 30 |
Major Applicable Materials | Metals (Steel, stainless steel, aluminum alloy, etc.) |
Curing Requirements | Apply pressure (50 ±20 kPa) for 24 hours at approx. 25°C. |
Category | 2 types of epoxy liquid mixed |
Capacity | 50 g (Main agent: 25 g) (Curing agent: 25 g) |
Features | Suitable for bonding gages for strain measurement at very low temperature. |
Major Applicable Gages | KFLB |
EP-340
Cured at normal temperature or by heating

Specifications
Types | Cured at normal temperature or by heating |
---|---|
Operating Temperature (℃) | -55 to 150 |
Major Applicable Materials | Metals (Steel, stainless steel, aluminum alloy, etc.) |
Curing Requirements | Apply pressure (100 ±50kPa) for 24 hours at approx. 25°C or for 2 hours at 80°C. |
Category | 2 types of epoxy liquid mixed |
Capacity | 30 g (Main agent: 6 g × 4) (Curing agent: 1.5 g × 4) |
Features | Suitable for bonding gages for strain measurement at mid temperature. |
Major Applicable Gages | KFGS, KFGT, KFRB, KFWB,KFWS, KC, KSPB,KSNB (Excl. E5), KSPH,KSPLB, KFSB, KFF, KCH |
EP-34B
Cured at normal temperature or by heating

Specifications
Types | Cured at normal temperature or by heating |
---|---|
Operating Temperature (℃) | -55 to 200 |
Major Applicable Materials | ・Metals (Steel, stainless steel, copper, aluminum alloy, etc.) ・Plastics (Acrylate, PVC, etc.) ・Composite materials (CFRP, GFRP, PCB, etc.) |
Curing Requirements | ・Apply pressure (30 to 50 kPa) for 24 hours at approx. 25℃ or for 2 hours at 80℃. ・Pressing is possible with tape. |
Category | 2 types of epoxy liquid mixed |
Capacity | 30.8 g (Main agent: 5.6 g × 4) (Curing agent: 2.1 g × 4) |
Features | Suitable for bonding gages for strain measurement at mid temperature and for bonding gages for transducers. |
Major Applicable Gages | KFRPB, KFP, KFHB |
EP-370
For bonding gages embeddable in bolts

Specifications
Types | Cured by normal temperature + heating |
---|---|
Operating Temperature | Normal temperature to 50 |
Major Applicable Materials | ・Metals (Steel, stainless steel, copper, aluminum alloy, etc.) ・Plastics (Acrylate, PVC, etc.) |
Curing Requirements | Keep at normal temperature for 24 hours and heat it for 5 hours at 80 ℃. |
Category | 2 types of epoxy liquid mixed |
Capacity | 40 g (Main agent: 30 g) (Curing agent: 10 g) |
Features | Low viscosity makes it suitable for bonding gages (KFB) in bolts. |
Major Applicable Gages | KFB |
PC-600
Cured by heating

Specifications
Types | Cured by heating |
---|---|
Operating Temperature (℃) | -269 to 250 |
Major Applicable Materials | Metals (Steel, Stainless steel, copper, aluminum alloy, etc.) |
Curing Requirements | Apply pressure (150 to 300 kPa) for 1 hour at 80°C → 2 hours at 130°C → 2 hours at 150°C. |
Category | 1 heating type of phenol liquid |
Capacity | 100 g |
Features | Suitable for bonding gages for strain measurement at low, mid and high temperatures and for bonding gages for transducers. |
Major Applicable Gages | KFGS, KFRB, KFHB, KFLB, KFNB |
PI-32
Cured by heating

Specifications
Types | Cured by heating |
---|---|
Operating Temperature (℃) | -269 to 350 |
Major Applicable Materials | Metals (Steel, stainless steel, copper, aluminum alloy, etc.) |
Curing Requirements | Apply pressure (200 to 500 kPa) for 1 hour at 100°C → 2 hours at 200°C → Remove pressure and perform aging.*1 *1 Place it in a heating furnace or the like, and perform aging according to the following requirement. (A temperature increasing speed should be about 5°C/minute.) [KFU gage] Increase heating temperature from room temperature to 300°C, then maintain 300°C for 2 hours. [KFHB gage] Increase heating temperature from room temperature to 250°C, then maintain 250°C for 2 hours. *If it is difficult to heat at 200°C, 2 h at 200°C may be changed to 5 h at 160°C with all other conditions followed. |
Category | 1 heating type of polyimide liquid |
Capacity | 20 g |
Features | Suitable for bonding gages for strain measurement at high temperature. |
Major Applicable Gages | KFU, KFHB |
PC-12B
Cured at room temperature

Specifications
Types | Cured at room temperature |
---|---|
Operating Temperature (℃) | -196 to 250 |
Major Applicable Materials | ・Metal (Steel, stainless steel, copper, aluminum alloys, etc.) ・Concrete ・Mortar |
Curing Requirements | Apply pressure (30 to 50kPa) for 2 hours. Release the pressure and cure it for 24 hours. |
Category | 2 type of polyester liquid mixed |
Capacity | 32 g (Main agent: 30 g) (Curing agent: 2 g) |
Features | Suitable for bonding semiconductor gages or gages for concrete strain measurement (KC and KFGS). |
Major Applicable Gages | KFGS, KC, KSPB, KSPH, KSPLB |
Law | Air transport prohibited |
EP-17
Cured by heating

Specifications
Types | Cured by heating |
---|---|
Operating Temperature (℃) | -50 to 170 |
Major Applicable Materials | Metal (Steel, stainless steel, copper, aluminum alloys, etc.) |
Curing Requirements | After finger pressure, apply tape pressure while heating it for cure for 2 hours at 130℃, 2 hours at 150℃ |
Category | Epoxy liquid and power mixed |
Capacity | 30 g |
Features | Dedicated for semiconductor gages (KSN-2-120-E5) . (Shrinked after curing) |
Major Applicable Gages | KSNB-2-E5 |
S-7
Curing agent

Specifications
Types | Curing promotion agent |
---|---|
Capacity | 25 g |
Features | A curing promotion agent to be used with instantaneous adhesive CC-33A (Applicable environment, low in temperature and dry such as in winter) |
S-9B
Surface treatment agent

Specifications
Types | Surface preparing agent |
---|---|
Capacity | 40 g |
Features | Aims to promote adhesive strength of the adhesive used to bond a strain gage onto plastics such as polyester, nylon 66, polyproperen, and polyethylene, which hardly accept adhesives. (As a surface preparing agent) |
Remarks
Note: The stated operating temperature range is for the adhesive only, and may differ depending on combinations with gages. When using the adhesives and gages together, read the attached instruction manual carefully.
eBook
Download
Catalogs
Manual
- CC-33A INSTRUCTION MANUAL (1.7MB)
- CC-35 INSTRUCTION MANUAL (467KB)
- CC-36 INSTRUCTION MANUAL (1.3MB)
- EP-17 INSTRUCTION MANUAL (394KB)
- EP-270 INSTRUCTION MANUAL (175KB)
- EP-340 INSTRUCTION MANUAL (254KB)
- EP-370 INSTRUCTION MANUAL (185KB)
- EP-34B INSTRUCTION MANUAL (1.5MB)
- PC-12B INSTRUCTION MANUAL (523KB)
- PC-600 INSTRUCTION MANUAL (243KB)
- PI-32 INSTRUCTION MANUAL (581KB)
- S-7 INSTRUCTION MANUAL (336KB)