Upgrade history PCAS-200A

Ver. 02.03

  • Enabled inputting comments of up to 400 characters on reports.
  • Enabled displaying graph reports by the gage.
  • Enabled displaying color-code threshold values by the parts while displaying all data collectively on single graph report.
  • Fixed the following bug.
    When you enlarge character sizes on the OS settings, characters did not appear correctly on the [Selecting] window.

Ver. 02.02

  • Added the "Combining data" function.
  • Enabled the scale settings of every report page.
  • Added the offset settings on "Threshold" window.
  • Enabled the pasting of table-reports as texts onto spreadsheets by copying.
  • Added the "Worst table", which displays the maximum ratio data to thresholds, on report windows.
  • Fixed the following bug.
    The guidance characters lacked after enlarging the OS font sizes.

Ver. 02.01

  • Fixed the following bug.
    When the number of reports were large, the PC hung.
  • Fixed the following bug.
    When the threshold type was “Auto” and strain speed was 0 on the “Table Report”, 0 appeared on the “Threshold” column and 1 appeared on the “%” column.
  • Fixed the following bug.
    Images did not appear correctly on the “Gage selection” of the “Catalog” window.
  • Started supporting Windows®, 10 from this version.

Ver. 02.00

  • Entering of product key and license key are required.
  • Added the gage selection guidance and gage bonding guidance.
  • Enabled to load the KS2 files of up to 128 channels.
  • Enabled to assign the multiple channels simultaneously on the “Locating” window.
  • Enabled to display the "direction of principal strain" angle on the "Reproduce" window and "Creating reports" window.
  • Enabled to add/delete markers on the "Reproduce" window - Detailed graph.
  • Enabled to execute data thinning when outputting the CSV files.
  • Enabled to set 2 threshold values on the "Creating reports" window.

Ver. 01.02

  • Fixed the following bug.
    The PCAS indicated the data of incorrect gages on the “Component” tab of table reports.
    Details:
    When you located multiple gages on a single component, and when the Maximum Strain of the latter-located gage was larger than that of the former-loaded gage, latter gage data appeared regardless of the % value.
    * In the right situation, gage data of the largest % appears.
  • Fixed the following bug.
    When you reproduced the strain rate, the Max Principal Strain appeared, instead of the Principal Strain, on the overview graphs.
  • Fixed the following bug.
    When you printed data without selecting the table report tab, 0 appeared as table report values.
  • Fixed the following bug.
    The PCAS did not update changed logo images.
  • Fixed the following bug.
    When you loaded the KS2 files - recorded at the sampling frequency of 5 Hz or less - and opened the [Detailed settings] window, the PC hung.
  • Fixed the following bug.
    When you deleted pre-located gages and relocated them on the [Locating] window, 0 appeared as table report values.
  • Fixed the following bug.
    When you loaded the KS2 files - created by using the PCAS-100A, the channel names did not appear on the [Connecting] window.
  • Fixed the following bug.
    When you loaded the KS2 files and loaded other KS2 files - created by using the PCAS-100A, the part of the pre-loaded KS2 file information appeared.
  • Fixed the following bug.
    When creating KYOWA¥PCAS-200A folders in document folders was not available, the PC hung.

Ver. 01.01

  • The automatically input function of judgment results to the table report has been added.