Temperature Effect on Lead Wire with 2-wire System
Lead wire Model | Cross-section (mm2) | Reciprocating Resistance of 1 m long Lead wire approx. (Ω) | Apparent Strain※ with 1m Extension approx. (μm/m℃) |
---|---|---|---|
L-5 L-9 L-6 |
0.5 0.11 0.08 0.015 |
0.07 0.32 0.44 2.24 |
1.13 5.06 6.90 35.7 |
Thermally-induced apparent strain ε r (μm/m/°C) is calculated by the following equation.