LMA-A
Small-sized Compression Load Cell

LMA-A

Summary

The LMA-A is a compact & lightweight load cell for measuring compressive loads.

Rated Capacity: 5 N to 1 kN
Diameter: 12 mm (5 to 50 N), 20 mm (100 N to 1 kN)
Nonlinearity: Within ±1% RO

Features

• Moderate price
• Easy installation
• Suitable for distributed loads measurement using multiple load cells

Relative images

CFM-A

Products table

All display

LMA-A-5N
5 N

Specifications

Performance
Rated Capacity 5 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.6 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.3% RO/ºC
Temperature Effect on Output Within ±0.2%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 15.3 kHz
Weight Approx. 1.5 g (Excluding cable)
Materials Copper alloy
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-10N
10 N

Specifications

Performance
Rated Capacity 10 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.2% RO/ºC
Temperature Effect on Output Within ±0.2%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 17.5 kHz
Weight Approx. 1.5 g (Excluding cable)
Materials Copper alloy
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-20N
20 N

Specifications

Performance
Rated Capacity 20 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.2% RO/ºC
Temperature Effect on Output Within ±0.2%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 24.8 kHz
Weight Approx. 1.5 g (Excluding cable)
Materials Copper alloy
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-50N
50 N

Specifications

Performance
Rated Capacity 50 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.2% RO/ºC
Temperature Effect on Output Within ±0.2%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 32.6 kHz
Weight Approx. 1.5 g (Excluding cable)
Materials Copper alloy
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-100N
100 N

LMA-A

Specifications

Performance
Rated Capacity 100 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 21.6 kHz
Weight Approx. 11 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-200N
200 N

LMA-A

Specifications

Performance
Rated Capacity 200 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 29.7 kHz
Weight Approx. 11 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-500N
500 N

LMA-A

Specifications

Performance
Rated Capacity 500 N
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 43.9 kHz
Weight Approx. 11 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

LMA-A-1KN
1 kN

LMA-A

Specifications

Performance
Rated Capacity 1 kN
Nonlinearity Within ±1% RO
Hysteresis Within ±1% RO
Repeatability 1% RO or less
Rated Output 0.75 to 2 mV/V
Environmental Characteristics
Safe Temperature -10 to 60ºC (Non-condensing)
Compensated Temperature 0 to 50ºC (Non-condensing)
Temperature Effect on Zero Within ±0.05% RO/ºC
Temperature Effect on Output Within ±0.05%/ºC
Electrical Characteristics
Safe Excitation 7 V AC or DC
Recommended Excitation 1 to 5 V AC or DC
Input Resistance 350 Ω ±2.5%
Output Resistance 350 Ω ±2.5%
Cable 4-conductor (0.035 mm2) vinyl shielded cable, 1.7 mm diameter by 2 m long, bared at the tip
(Shield wire is not connected to the case.)
Mechanical Properties
Safe Overloads 150%
Natural Frequencies Approx. 53.0 kHz
Weight Approx. 11 g (Excluding cable)
Materials Stainless steel
Degree of Protection IP64 (IEC 60529)
Optional Accessories Mount Base CFM-A

Dimensions

LMA-A

Mount Base

CFM-5A
Mount Base

CFM-A
Object Product Model LMA-A-5N
LMA-A-10N
LMA-A-20N
LMA-A-50N

CFM-100A
Mount Base

CFM-A
Object Product Model LMA-A-100N
LMA-A-200N
LMA-A-500N
LMA-A-1KN

Page Top

Remarks

*CE compliant models are available. Inquiries are welcome.

eBook

Download

Recommended products for combination